© 2023 Sungrow Power Supply Co, . Ltd . All rights reserved . Subject to change without notice . Version 19 Up to 16 MPPTs with max. efficiency 99% 20A per string, compatible with 500Wp+ module Data exchange with tracker system, improving yield HIGH YIELD Q at night function, save investment Power line communication (PLC) Smart IV Curve diagnosis, active O&M LOW COST SCR≥1. 15 stable operation in extremely weak grid Reactive power response time < 30ms Compliant with global grid code GRID SUPPORT 2 strings per MPPT, no fear of string reverse connection 24h real-time AC and DC insulation monitoring PROVEN SAFETY CIRCUIT DIAGRAM EFFICIENCY CURVE SG350HX Multi-MPPT String Inverter for 1500 Vdc System L1 L2 L3 AC SPD PE DC1 DC switch DC Bus Inverter circuit AC Filter AC Relay AC EMI DC12 Current Monitoring MPPT (1) MPPT (12) DC EMI DC SPD Normalized Output Power 88% 90% 92% 94% 96% 98% 100% 5% 10% 20% 30% 50% 75% 100% Vdc=860V Vdc=1168V Vdc=1300V Efficiency © 2023 Sungrow Power Supply Co, . Ltd . All rights reserved . Subject to change without notice . Version 19 *Due to the multi-supplier for some key components, the actual weight may have a ±8% deviation, please refer to the actually delivered product. Type designation Input (DC) Max. PV input voltage Min. PV input voltage / Startup input voltage Nominal PV input voltage MPP voltage range No. of independent MPP inputs Max.

number of input connector per MPPT Max. PV input current Max. DC short-circuit current per MPPT Output (AC) AC output power Max. AC output current Nominal AC voltage AC voltage range Nominal grid frequency / Grid frequency range THD DC current injection Power factor at nominal power / Adjustable power factor Feed-in phases / Connection phases Efficiency Max. efficiency / European efficiency Protection DC reverse connection protection AC short circuit protection Leakage current protection Grid monitoring Ground fault monitoring DC switch / AC switch PV string current monitoring Q at night function Anti-PID and PID recovery function Surge protection General Data Dimensions (W*H*D) Weight* Isolation method Degree of protection Power consumption at night Operating ambient temperature range Allowable relative humidity range Cooling method Max. operating altitude Display Communication DC connection type AC connection type Compliance Grid Support 1500 V 500 V / 550 V 1080 V 500 V – 1500 V 12 (Optional: 14 / 16) 2 12 * 40 A (Optional: 14 * 30 A / 16 * 30 A) 60 A 352 kVA @ 30℃ / 320 kVA @ 40 ℃ / 295 kVA @ 50℃ 254 A 3 / PE, 800 V 640 – 920 V 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz < 3 % (at nominal power) < 0. 5 % In > 0. 99 / 0. 8 leading – 0. 8 lagging 3 / 3 99. 02 % / 98.

8 % Yes Yes Yes Yes Yes Yes / No Yes Yes Optional DC Type II / AC Type II 1136 * 870 * 361 mm ≤ 116 kg Transformerless IP66 < 6 W -30 to 60℃ 0 – 100 % Smart forced air cooling 4000 m ( > 3000 m derating) LED, Bluetooth+APP RS485 / PLC MC4-Evo2 (Max. 6 mm², optional 10mm²) Support OT/DT terminal (Max. 400 mm²) IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N 4110: 2018, VDE-AR-N 4120: 2018, EN 50549-1/2, UNE 206007-1: 2013, P. O. 12. 3, UTE C15- 712-1: 2013 Q at night function, LVRT, HVRT, active & reactive power control and power ramp rate control, Q-U control, P-f control SG350HX

De tekst is automatisch uit het bestand gehaald en kan afwijken van het origineel (kolommen, tabellen en koppen lopen door elkaar). Het officiële stuk bij iBabs is leidend. Bron: https://steenwijkerland.bestuurlijkeinformatie.nl/Document/LoadAgendaItemDocument/dc1da8cf-6c71-407c-8636-db511ed58168?agendaItemId=a16056c6-e554-4670-a12d-03558c806aec