Noise Notes 4-4

30/03/06

8:22 am

Page 15

noise notes

The Beat is Getting Stronger: The Effect of Atmospheric Stability on Low Frequency Modulated Sound of Wind Turbines G.P. van den Berg University of Groningen – Science Shop for Physics Nijenborgh 4, 9747AG Groningen, the Netherlands g.p.van.den.berg@rug.nl

Sound from wind turbines involves a number of sound production mechanisms related to different interactions between the turbine blades and the air. An important contribution to the low frequency part of the sound spectrum is due to the sudden variation in air flow which the blade encounters when it passes the tower: the angle of attack of the incoming air suddenly deviates from the angle that is optimized for the mean flow. Hitherto, low-frequency sound from wind turbines has not been shown to be a major factor contributing to annoyance. This seems reasonable as the blade passing frequency is of the order of one hertz where the human auditory system is relatively insensitive. This argument, however, obscures a very relevant effect: the blade passing frequency modulates well audible, higher-frequency sounds and thus creates periodic sound: blade swish. This effect is stronger at night because in a stable atmosphere there is a greater difference between rotor averaged and near-tower wind speed. Measurements have shown that additional turbines can interact to further amplify this effect. Theoretically the resulting fluctuations in sound level will be clearly perceptible to human hearing.

This is confirmed by residents near wind turbines with the same common observation: often late in the afternoon or in the evening the turbine sound acquires a distinct ‘beating’ character, the rhythm of which is in agreement with the blade passing frequency. It is clear from the observations that this is associated to a change toward a higher atmospheric stability. The effect of stronger fluctuations on annoyance has not been investigated as such, although it is highly relevant because a) the effect is stronger for modern (that is: tall) wind turbines, and b) more people in Europe will be living close to these wind turbines as a result of the growth of wind energy projects.

1. INTRODUCTION Modern onshore wind turbines have peak electric power outputs of around 2 Mw and tower heights of 80 to 100 meters. In 2003, 75% of the global wind power peak electric output of 40 Gw was installed in the European Union. The original European target for 2010 was 40 Gw, but the European Wind Energy Association have already set a new target for 2010 of 75 Gw, of which 10 Gw is projected offshore, while others have forecast a peak output of 120 Gw for that year [1]. Whether this growth will actually occur is uncertain; with the proportional increase of wind energy in total electric power the difficulties and costs of integrating large scale windpower with respect to grid capacity and stability, reserve capacity and CO2 emission reductions are becoming more prominent (see, e.g., [31, 32]). However, further expansion of wind energy is to be expected, and as a result of this (predominantly on-shore) growth an increasing number of people may face the prospect of living near wind farms, and have reason to inquire and perhaps be worried about their environmental impact. Visual intrusion, intermittent reflections on the turbine blades, as well as intermittent shadows (caused when the rotating blades pass between the viewer and the sun), and sound, are usually considered potentially negative impacts.

Atmospheric stability has hitherto not been considered with respect to wind turbine sound. However, at the heights that are reached by modern, tall wind noise notes

volume 4 number 4

15

Noise Notes 4-4

30/03/06

8:22 am

Page 16

the beat is getting stronger KOREAN RAIL WAYS In Korea, the high-speed KTX trains were supposed to run quietly, according to the railway brochures and advertisements that promoted the bullet trains half a year go. KTX trains are electric and ride on seamless tracks to reduce noise and vibration, the advertising says, adding that the trains’ wheels are between the cars rather than under them, also contributing significantly to a quieter ride. But complaints have been received about the noisiness of the ride. After tests, the Korean National Railroad blamed the wheels, which are being chipped away or dented by gravel from the rail bed. As the trains pick up speed, gravel is lifted from the ground and strikes the wheels, officials explained. The problem is minor when the trains are running on the new track designed for the high-speed train, they said, but the problems become serious on the stretches of old track where the trains still operated. Most of those operations are on the lines from Seoul to the southwestern Jeolla provinces. The Korean National Railroad has found more than 100 damaged wheels per month since the KTX began regular service in April. “Dented wheels are like punctured wheels on a car,” said Kim Seok-won of the Korea Railroad Research Institute.

“It is slowing down the speed of the train, not to mention the uncomfortable ride.” The railroad said it is repairing the wheels to put them back in round, even though some experts say that could shorten the lifespan of the wheels by more than 20 per cent. One official said a possible solution, now being studied, would be to remove the rail bed gravel entirely. 16

turbines the effect has become increasingly important, from an energetic as well as acoustical point of view. In an earlier paper [2] it has been shown that in a stable atmosphere the sound level due to wind turbines is higher than is expected from sound production based on simple logarithmic extrapolation from reference wind speeds. The present paper explores the effect of atmospheric stability on the periodic level changes known as ‘blade swish’. In the next two sections three possibly relevant effects of a change in atmospheric stability are identified and investigated from a theoretical point of view. All effects result in a higher level of blade swish. Then, in section 4, we will turn to measurement results and show that measured results can be explained by these predicted effects. Finally, in section 5, the results are put in the context of human perception. It can now be understood why in a stable atmosphere (but not in an unstable atmosphere) wind turbine sound is perceived as a fluctuating sound.

2. SOURCES OF WIND TURBINE SOUND There are many publications on the nature and power of turbine sound. See, e.g., the studies by Lowson [3] and Grosveld [4], and the reviews by Hubbard and Shepherd [5] and Wagner et al [6]. A short introduction on wind aeroacoustics will be given to elucidate the most important sound producing mechanisms. If an air flow is smooth around a (streamlined) body, it will generate very little sound. For high speeds and/or over longer lengths the flow in the boundary layer between the body and the main flow becomes turbulent. The rapid turbulent velocity changes at the surface cause sound with frequencies related to the rate of the velocity changes. The turbulent boundary layer at the downstream end of an airfoil produces trailing edge sound, which is the dominant audible sound from modern turbines. As is the case for aircraft wings, the air flow around a wind turbine blade generates lift. An air foil performs best when lift is maximised and drag (flow resistance) is minimised. Both are determined by the angle of attack: the angle (α) between the incoming flow and the blade chord (line between front and rear edge; see figure 1). When the angle of attack increases from its optimal value the turbulent boundary layer on the suction (low pressure) side grows in thickness, thereby decreasing power performance and increasing sound level.

For high angles of attack this eventually leads to stall, that is: a dramatic reduction in lift. Apart from this turbulence inherent to an airfoil, the atmosphere itself is turbulent over a wide range of frequencies and sizes. Turbulence can be defined as changes over time and space in wind velocity and direction, resulting in velocity components normal to the airfoil varying with the turbulence frequency causing inflow turbulent sound. Atmospheric turbulence energy has a maximum at a frequency that depends on height and on atmospheric stability. For wind turbine altitudes this peak frequency is of an order of magnitude of once per minute (0.017 Hz). The associated eddy (whirl) scale is of the order of magnitude of several hundreds of meters [7] in an unstable atmosphere, less in a stable atmosphere. Eddy size and Air velocity due to rotation Velocity of incoming air

Figure 1

Blade velocity α

Wind speed Chord

Flow impinging on a turbine blade. volume 4 number 4

noise notes

Noise Notes 4-4

30/03/06

8:22 am

Page 17

the beat is getting stronger turbulence strength decrease at higher frequency, and vanish due to viscous friction when they have reached a size of approximately one millimetre. A third sound producing mechanism is the response of the blade to the change in lift when it passes the tower. The wind is slowed down by the tower which changes the angle of attack. The resulting sideways movement of the blade causes thickness sound at the blade passing frequency and its harmonics. A more thorough review of these three sound production mechanisms is given in Appendix I, where frequency ranges and sound levels are quantified in so far as relevant for the present paper. A modern wind turbine sound spectrum can now be divided in (overlapping) regions corresponding to these three mechanisms: 1. Infrasound frequency (f < 30 Hz): the thickness sound is tonal, the spectrum containing peaks at the blade passing frequency fB and its harmonics. 2. Low frequency: in-flow turbulent sound is broad-band noise with a maximum level at approximately 10 Hz and a slope of 3–6 dB per octave. 3. High frequency: trailing edge (TE) sound is noise with a maximum level at 500–1000 Hz for the central octave band, decreasing by 11 dB for neighbouring octave bands and more for further octave bands.

Sound originating from the generator or the transmission gear has decreased in level in the past decades and has become irrelevant when considering annoyance for residents. As thickness sound is not relevant for direct perception, turbulent flow is the dominant cause of (audible) sound for modern wind turbines. It is broad-band noise with no tonal components and only a little variation, known as blade swish. Blade swish is sound due to the regular increase in trailing edge sound whenever a blade passes the tower. Trailing edge (TE) sound level is proportional to 50 log M (see equation A4 in appendix), where M is the Mach number of the air impinging on the blade. TE sound level therefore increases steeply with blade speed and is highest at the high velocity blade tips. Swish thus originates predominantly at the tips. Sound from downwind rotors, i.e. with the rotor downwind from the tower, was considered problematic as it was perceived as a pulsating sound (see appendix). For modern upwind rotors this variation in sound level is weaker. It is not thought to be relevant for annoyance and considered to become less pronounced with increasing distance due to loss of the effect of directivity, due to relatively high absorption at swish frequencies, and because of the increased masking effect of background noise [8].

However, several effects that increase the level of the swishing sound and are related to increasing atmospheric stability have not been taken into account as yet. Possible effects will be considered before we turn to measurement results.

3. EFFECT OF ATMOSPHERIC STABILITY ON WIND TURBINE SOUND The wind speed vh at height h in the atmosphere can be written as: v h = v ref  h h  ref

m

(1)

where reference height href is usually 10 m [2, 7]. The relation is suitable where h is at least several times the roughness length. At high altitudes the wind profile will not follow (1), as eventually a more or less constant wind speed (the geostrophic wind) will be attained. At higher altitudes in a stable atmosphere there may be a decrease in wind speed when a nocturnal ‘jet’ develops. The maximum in this jet is caused by a transfer of kinetic energy from the near ground air that decouples from noise notes

volume 4 number 4

17

Noise Notes 4-4

30/03/06

8:22 am

Page 18

the beat is getting stronger higher air masses as large, thermally induced eddies vanish because of ground cooling. In fact, reversal of the usual near-ground diurnal pattern of low wind speeds at night and higher wind speeds in daytime is a common phenomenon at higher altitudes over land in clear nights [9, 10, 11]. Over large bodies of water the phenomenon may be seasonal as stability occurs more often when the water is relatively cold (winter, spring). This may also be accompanied by a maximum in wind velocity at a higher altitude [12]. In a neutral atmosphere the wind profile can also be modelled with the well known logarithmic or adiabatic profile, where relative wind speed vh/vref depends on height and surface roughness. This model is widely (and, as yet, only) used in relation to wind turbine sound (see, e.g., [8] or [14]). With regard to wind power more attention is being paid to stability effects and thus to other wind profile models [see, e.g., 10, 11, 12, 15, 16]. Accurate wind speed profiles can be calculated with a diabatic wind speed model where stability corrections are added to the adiabatic profile (see, e.g., [9] or [13]). Equation (l) has no theoretical basis, but often provides a good fit to the vertical wind profile, especially when the atmosphere is non-neutral. In flat terrain the stability exponent m has a value of 0.1 and more.

In daytime or in windy nights (0.1 < m < 0.2) equation (1) does not deviate much from the logarithmic wind profile: for altitudes up to 100 m and low vegetation (roughness length < 10 cm), wind velocities calculated with equation 1 agree within 20% with the logarithmic wind profile. For a neutral atmosphere, occurring under heavy clouding and/or in strong winds, m has a value of approx. 0.2. In an unstable atmosphere -occurring in daytime- thermal effects caused by ground heating are dominant. Then m has a lower value, down to approx. 0.1. In a stable atmosphere vertical movements are damped because of ground cooling. One would then eventually expect a parabolic 1 wind profile, as is found in laminar flow, corresponding to a value of m of 0.7 = 2 . Our measurements near the Rhede wind farm (53º 6.2′ latitude, 7º 12.6′ longitude) at the German-Dutch border [2] yielded values of m up to 0.6. A sample (averages over 0:00–0:30 GMT of each first night of the month in 1973) from data from a 200 m high tower in flat, agricultural land [27] shows that the theoretical value is indeed reached: in ten out of the twelve samples there was a temperature inversion in the lower 120 m, indicating atmospheric stability.

In six samples the temperature increased with more than l ºC from 10 to 120 m height and the exponent m (calculated from (1): m = log(v80/v10)/ log(8)) was 0.43, 0.44, 0.55, 0.58, 0.67 and 0.72. Comparable values have been estimated in the US Midwest [15] and at a Spanish plateau [16]. In the following text we will use a value m = 0.15 for a daytime atmosphere (unstable – neutral), m = 0.4 for a stable, and m = 0.65 for a very stable atmosphere. These values will be used for altitudes between 10 and 120 m. The magnitude of the effects of increasing stability depends on wind turbine properties such as speed, diameter and height. We will use the dimensions of the wind turbines in the Rhede wind farm, that are typical for a modem 1.5-2 MW wind turbine: hub height 100 m, blade length 35 m and rotational speed increasing with wind speed up to a maximum value of ΩR = 73 m/s (at 20 rpm). There are now three factors influencing blade swish level when the atmosphere becomes more stable: a) the higher wind speed gradient, b) the higher wind direction gradient, and c) the relative absence of large scale turbulence. a. Wind speed gradient. Rotational speed is determined by a rotor averaged wind speed. With increasing atmospheric stability the difference in wind speed between the upper and lower part of the rotor increases. Suppose that the wind 18

volume 4 number 4

noise notes

Noise Notes 4-4

30/03/06

8:22 am

Page 19

the beat is getting stronger

b.

speed at hub height is v100 = 14 m/s, corresponding to v10 = 9.8 m/s in a neutral atmosphere in flat open grass land (roughness length 4 cm). Then in daytime (m = 0.15) the wind speed at the lowest point of the rotor would be v65 = 13.1 m/s, at the highest point v135 = 14.6 m/s. As the blade angle does not change with rotation angle, the difference between the low tip and hub height wind speeds causes a change in angle of attack on the blade of ∆α = 0.8° at 20 rpm (see appendix, equation A7). Between the high tip and hub height the change is smaller: 0.5°. In night-time (m = 0.4), at the same wind speed at hub height, v65 is 11.8 m/s causing a change in angle of attack at the lower tip relative to hub height of 1.8° (at the high tip: v135 = 15.8 m/s, ∆α = 1.5°). When the atmosphere is very stable (m = 0.65), wind speed v65 = 10.5 m/s and the angle of attack on the low altitude tip deviates 2.9° from the angle at hub height (at the high tip: v135 = 17.0 m/s, ∆α = 2.5°). In fact when the lower tip passes the tower there is a greater mismatch between optimum and actual angle of attack α because there was already a change in angle of attack related to the wind velocity deficit in front of the tower.

For a daytime atmosphere and with respect to the situation at hub height, the change in α associated to a blade swish level of 1 ± 0.5 dB is estimated as 2.1 ± 0.4° (see appendix, section C), part of which (0.8°) is due to the wind profile and the rest to the tower. The increase in α due to the stability related wind profile change must be added to this daytime change in α. Thus, relative to the daytime (unstable to neutral) atmosphere, the change in angle of attack when the lower tip passes the mast increases with 1.0° in a stable atmosphere, and with 2.1° in a very stable atmosphere. The associated change in trailing edge (TE) sound level, as calculated from equation A6 in the appendix, is 3.1 ± 0.7 dB for a stable and 5.0 ± 0.8 dB for a very stable atmosphere (compared to 1 ± 0.5 dB in daytime). The corresponding total A-weighted sound level will be somewhat less as trailing edge sound is not the only sound source (but it is the dominant source; see section 4C). At the high tip the change in angle of attack is smaller than for the low tip as there is no (sudden) tower induced change to add to the wind gradient dependent change. The change in angle of attack at the high tip in a very stable atmosphere (2.5°) is comparable to the change at the low tip in daytime, and this change is more gradual than for the low tip.

Thus we find that, for vl00 = 14 m/s, the 1-2 dB daytime blade swish level increases to approx. 5 dB in a very stable atmosphere. The effect is stronger when wind speed increases up to the point where friction turbulence overrides stability and the atmosphere becomes neutral. The increase in trailing edge sound level will be accompanied by a lower peak frequency (see appendix, equation A2). For α = 5° the shift is one octave. Wind direction gradient. In a stable atmosphere air masses at different altitudes are only coupled by small scale turbulence and are therefore relatively independent. Apart from a higher velocity gradient a higher wind direction gradient is also possible, and with increasing height the wind direction may change significantly. This wind direction shear will change the angle of attack with height. Assuming the wind at hub height to be normal to the rotor, the angle of attack will decrease below and increase above hub height (or vice versa). This effect, however, is small: if we suppose a change in wind direction of 20° over the rotor height at a wind velocity of 10 m/s, the change in angle of attack between extreme tip positions at 20 rpm is only 0.25°, which is negligible relative to the wind velocity shear.

noise notes

volume 4 number 4

19

Noise Notes 4-4

30/03/06

8:22 am

Page 20

the beat is getting stronger c.

Less turbulence. As was shown in an earlier study [2], in areas near a wind farm an increase in blade swish pulse height (the term ‘pulse’ is used to indicate the upward variation in sound level) can be explained by the synchronization of two or three pulse trains coming from the two or three closest turbines. In a stable atmosphere wind turbines can run almost synchronously because the absence of large scale turbulence leads to less variation superimposed on the constant (average) wind speed at each turbine. In unstable conditions the average wind speed at both turbines will be equal, but instantaneous local wind speeds will differ because of the presence of large, turbulent eddies at the scale of the inter-turbine distance. In a stable atmosphere the turbulence scale decreases with a factor up to 10, relative to the neutral atmosphere and even more relative to an unstable atmosphere [17]. In stable conditions turbines in a wind farm therefore experience a more similar wind and as a consequence their instantaneous turbine speeds are more nearly equal. This is confirmed by long term measurements by Nanahara et al. [18] who analysed coherence of wind speeds between different locations in two coastal areas. At night wind speeds at different locations were found to change more coherently than they did at daytime [19].

The difference between night and day was not very strong, probably because time of day on its own is not a sufficient indicator for stability. The decay of coherence was however strongly correlated with turbulence intensity, which in turn is closely correlated to stability. (In a coastal location atmospheric stability also depends on wind direction as landwards stability is a diurnal, but seawards a seasonal phenomenon. Also, a fixed duration for all nights in a year does not coincide with the time that the surface cools (between sundown and sunrise), which is a prerequisite for stability.) Near the Rhede wind farm we found that, because of the near-synchronicity of several turbines, sometimes two or three were in phase and the blade passing pulses coincided, and then went out of phase again [2]. This would lead to a doubling (+3 dB) or tripling (+5 dB) of pulse height. If in a (very) stable atmosphere individual swish pulse heights are 3–5 dB (see section 3a above), synchronicity at the Rhede wind farm or similar configurations would thus lead to pulse heights of 6–10 dB. Synchronicity here refers to the sound pulses from the different turbines as observed at the location of the observer. So, pulses synchronise when they arrive simultaneously.

This is determined by differences in phase (rotor position) between turbines and in propagation distances of the sound from the turbines. Phase differences between turbine rotors occur because turbines are not connected and because of differences in actual performance. The place where synchronicity is observed will change when the phase difference between turbines changes. With exact synchronicity there would be a fixed interference pattern, with synchronicity at fixed spots. Because of near-synchronicity however, synchronicity will change over time and place and an observer will hear coinciding pulses for part of the time only. A second effect of the decrease in turbulence strength is that in-flow turbulent sound level also decreases. The resulting decrease in broad band sound level lowers the minimum in the temporal variations, thereby increasing modulation depth. We conclude that the higher wind speed gradient and (near-) synchronicity increase blade swish levels at some distance from a wind farm. The higher infrasound level due to extra blade loading is not perceptible because of the high hearing threshold at the very low blade passing frequency. However, the effect of added boundary layer turbulence on the blade increases the levels at the higher 20

volume 4 number 4

noise notes

Noise Notes 4-4

30/03/06

8:22 am

Page 21

the beat is getting stronger frequencies that already were dominating the most audible part of the sound. Near a wind farm the variation in sound level will depend on the distances of the wind turbines relative to the observer: the level increase due to several turbines will reach higher levels when more turbines are at approximately equal distances and thus contribute equal immission levels. The increase in level variation, or beating, is thus at well-audible frequencies and has a repetition rate equal to the blade passing frequency. Thus, theoretically it can be concluded that in stable conditions (low ambient sound level, high turbine sound power and higher modulation or swish level) wind turbine sound can be heard at greater distances and is of lower frequency due to absorption and the frequency shift of swish sound. It is thus a louder and more lowfrequency ‘thumping’ sound and less the swishing sound than observed close to a daytime wind turbine.

4. MEASUREMENT RESULTS 4.1. LOCATIONS In the summers of 2002 and 2004 wind turbine sounds have been recorded in and near the Rhede wind farm on the German-Dutch border. The farm (figure 2) has a straight south to north row of ten turbines at approximately 300 m intervals, running parallel to the border, and seven less regularly spaced turbines east of the straight row. Each turbine is 98 m to the hub height, and has a blade length of 35 m, and produces nominally 1.8 MW electric power. The measurement location at dwelling R is west of the turbines, 625 m from the nearest turbine. The microphone position was at 4 m height and close to the house, but with no reflections except from the ground. The measurement location at dwelling P, 870 m south of R, was 1.5 m above a paved terrace in front of the facade of the dwelling at 750 m distance from the nearest turbine. The entire area is quiet, flat, agricultural land with some trees close to the dwellings. There is little traffic and there are no significant permanent human sound sources. A third dwelling Z is in Boazum in the northern part of the Netherlands, 280 m west of a single, two-speed turbine (45 m hub height, 23 m blade length, 20/26 rpm). The area is again quiet, flat and agricultural. The immission measurement point is at 1.5 m height above gravel near the dwelling.

This measurement site is included here to show that the influence of stability on blade swish levels occurs also with smaller, single turbines. At all locations near dwellings the microphone was fitted in a 9 cm diameter foam wind screen. Table I gives an overview of measurement (start) times and dates of observed turbine speeds and of wind speed and direction, for situations for which results will be given below. The wind speed at hub height vhub has been determined from turbine rotation speed N or sound power level Lw ([2], the relation vhub– N follows from ref. 3 and 11 in [1]). The wind speed v10 at 10 m height was continuously measured at or near location A, except for location Z, where data from several meteorological stations were used showing that the wind was similar and nearly constant in the entire northern part of the Netherlands. In all cases there were no significant variations in wind speed at the time of measurement. Wind speed at the microphone was lower than v10 because of the low microphone height and shelter provided by trees nearby. Wind direction is given in degrees relative to north and clockwise (90° is east). The spectra near a turbine were measured with the microphone just above a hard surface at ground level 100 m downwind of a turbine noise notes

volume 4 number 4

21

Noise Notes 4-4

30/03/06

8:22 am

Page 22

the beat is getting stronger TIGHTER ORDINANCES

Border D

NL

Increasingly, townships in America are turning away from noise ordinances that rely on decibel-measuring equipment to establish the fact of excessive noise, and adopting the view that if noise can be heard 50 feet from its source, it is ipso facto “excessive”, and so merits a penalty. One advantage is that this kind of ordinance gives defendants (lawyers) less wiggle room – out go all the arguments about the sound meter not being properly calibrated, the operator not being properly trained, etc., etc. If Officer Smith can hear you at 50 feet, you’re guilty. Certainty, and simplicity, is leading to more prosecutions. In Fredericksburg, Virginia, under the old rules, police took just two people to court in the first seven months of 2003; from August 2003 to March 2004 26 people were taken to court, under the new rules. The re-writing of the rules so that the prosecution must win is going to have the most profound effect on the public noise-scape.

R

16

B

P

A 7 N 1

0

Figure 2

500

1000 m

Turbines (grey circles) in and measurement locations (A,B,P,R) near the Rhede wind farm; solid lines are roads.

in compliance with IEC 61400 [14] as much as possible (non-compliance did not lead to differences in result [2]; for reasons of non-compliance, see [34]). The levels plotted are immission levels: measured Leq minus 6 dB correction for coherent reflection against the hard surface [16]. The plotted levels near the dwellings are also immission levels: measured Leq minus 3 dB correction for incoherent reflection at the façade for dwelling P, or measured Leq without any correction for dwellings R and Z. At dwelling P at the time of measurement the beat in the turbine sound was very pronounced. In the other measurements (dwellings R and Z) the beating was not as loud. The measurements near turbine 16 and dwelling R at 23:07 on September 9 were performed simultaneously.

4.2. FREQUENCY RESPONSE OF INSTRUMENTS For the Rhede measurements sound was recorded on a TASCAM DA-1 DATrecorder with a precision 1in Sennheiser MKH 20 P48 microphone. The sound was

Table I. Overview of measurement locations and times and of turbine speed and wind

Location Dwelling P Turbine 7 Turbine 1 Dwelling R Turbine 16 Dwelling Z

22

Measurement Date Time June 3, 2002 00:45 June 3, 2002 06:30 June 3, 2002 06:45

Turbine speed (rpm) 20 19 19

Wind speed (m/s) v10 vhub 5 14 5 15 5 15

Wind direction (° north) 100 100 100

Sep. 9, 2004

23:07

18

4

14

80

Oct. 18, 2003

01:43

26

3

6

60

volume 4 number 4

noise notes

Noise Notes 4-4

30/03/06

8:22 am

Page 23

the beat is getting stronger NEIGHBOURS A nuisance neighbour who caused two years of misery for other residents has been evicted from her Walthamstow, east London, home. The 23-year-old’s antisocial behaviour included latenight noise such as banging doors, running up and down stairs, moving furniture and shouting. The trouble flared just weeks after the woman moved into the flat in the Blackhorse Road area in March 2002. She signed an acceptable behaviour contract in September 2002, under which she agreed to improve her ways. The problems continued and Waltham Forest Council took her to court twice. This led to her recent eviction. Hassett Auguste, chief executive of Ascham Homes which manages homes on behalf of the council, said: “We do everything we can to deal amicably with behaviour such as this, but ultimately people must take responsibility for their own actions.” GETTING THE BIRD

Figure 3

noise notes

Left axis (in dB): 200 consecutive, unweighted and 1 second spaced 1/3 octave band levels (thin lines), and average spectral level (thick line) near turbines I and 7, and near dwelling P; right axis: coefficient of correlation (line with markers) at each 1/3 octave band frequency between all 200 1/3 octave band levels and overall A-weighted levels.

volume 4 number 4

City Hall, Portland, Maine, is being made home by pigeons in unusually large numbers this year. So the city has bought a $500 solar powered machine that blares out electronic shrieks, intended to scare off the pigeons. Choosing the solar machine was, city officials say, essentially a cost and environmental issue. Unfortunately, it appears not to work. 23

Noise Notes 4-4

30/03/06

8:22 am

Page 24

the beat is getting stronger then sampled in 1-second intervals on a Larson Davis 2800 frequency analyser. From 1 to 10 000 Hz the frequency response of the DAT-recorder and LD2800 analyser have been determined with a pure tone electrical signal as input. The LD2800 response is flat (±1 dB) for all frequencies. The DAT-recorder is a first order high pass filter with a corner frequency of 2 Hz. The frequency response of the microphone was of most influence and has been determined relative to a B&K 1⁄2 in microphone type 4189 with a known frequency response [20]. Equivalent spectral sound levels with both microphones in the same sound field (approx. 10 cm mutual distance) were compared. For frequencies of 2 Hz and above the entire measurement chain is within 3 dB equivalent to a series of two high pass filters with corner frequencies of f1 = 4 Hz and f2 = 9 Hz, or a transfer function equal to -20log[l + (f1/f)2] -20log[l + ( f2/f)2]. For frequencies below 2 Hz this leads to high signal reductions (< -40 dB) and consequentially low signal to (system) noise ratios. Therefore values at frequencies < 2 Hz are not presented. For the Boazum measurements sound was recorded on a Sharp MD-MT99 minidisc recorder with a 1in Sennheiser ME62 microphone. The frequency response of this measurement chain is not known, but is assumed to be flat in the usual audio frequency range.

Simultaneous measurements of the broad band Aweighted sound level were done with a precision (type 1) sound level meter. Absolute precision is not required here as the minidisc recorded spectra are only used to demonstrate relative spectral levels. Because of the ATRAC time coding of a signal, a minidisc recording does not accurately follow a level change in a time interval < 11.6 ms. This is insignificant in the present case as the ‘fast’ response time of a sound level meter is much slower (125 ms).

4.3. MEASURED EMISSION AND IMMISSION SPECTRA Recordings were made at evening, night or early morning. On June 3, 2002, sound was recorded at dwelling P at around midnight and early in the morning near two turbines (numbers 1 and 7). At P at these times a distinct beat was audible in the wind turbine sound. In figure 3, 1/3 octave band spectra of the recorded sound at P and at both turbines have been plotted. In each figure A, B and C, 200 sound pressure spectra sampled in one-second intervals, as well as the energy averaged spectrum of the 200 samples have been plotted. The standard deviation of 1/3 octave band levels is typically 7 dB at very low frequencies, decreasing to approx. 1 dB at 1 kHz. The correlation coefficient ρ between all unweighted l/3 octave band levels and the overall A-weighted sound level has also been plotted for each 1/3 octave band frequency. For frequencies below approximately 10 Hz the sound is dominated by the thickness sound associated with the blade passing frequency and harmonics. In the rest of the infrasound region and upwards, in-flow turbulence is the dominant sound producing mechanism. Gradually, at frequencies above 100 Hz, trailing edge sound becomes the most dominant source, declining at high frequencies of one to several kHz.

Trailing edge sound is more pronounced at turbine 1 (T1) compared to turbine 7 (T7), causing a hump near 1000 Hz in the T1 spectra. At very high frequencies (> 2 kHz) sometimes higher spectral levels occur due to birds. It is clear from the spectra that most energy is found at lower frequencies. However, most of this sound is not perceptible. To assess the infrasound level relevant to human perception it can be expressed as a G-weighted level [30], With G-weighting sound above the infrasound range is suppressed. The average infrasound perception threshold is 95 dB(G) [28]. The measured G-weighted levels are 15-20 dB below this threshold: 80.5 and 81.1 dB(G) near turbines 1 and 7 respectively, and 76.4 dB(G) at the façade. 24

volume 4 number 4

noise notes

30/03/06

8:22 am

Page 25

the beat is getting stronger A

1/3 octave band L10, Leq, L90 (dB)

80

Turbines 1 & 7 60

Dwelling P 40

20 1

10

Octave band L10-L90 (dB)

5

100 frequency (Hz)

1000

Turbines

Dwelling P

3

10000

1 −1

B

1/3 octave band L95, Leq, L5 (dB)

80

Turbine 16

60

40 Dwelling R 20 1

10

100 Frequency (Hz)

Octave band L5-L95 (dB)

5

1000

10000

Turbine 16

3 1

Dwelling R

−1

C

1/3 octave band L95, Leq, L5 (dB)

60 Dwelling Z 40

20 1

10

100 Frequency (Hz)

1000

10000

5 Octave band L5-L95 (dB)

Noise Notes 4-4

3 1 −1

Figure 4

noise notes

Upper panels A,B,C: 1/3 octave band Leq near windturbines and dwellings (thick lines) and Leq of all samples with resp. 5% highest (thin dotted lines) and 5% lowest values of broad band LA (thick dotted lines). Lower panels: difference between Leq of 5- and 95-percentile octave band levels. volume 4 number 4

WEEKEND CONSTRUCTION City councillors want to stop developers from operating on major construction sites over long weekends to ease noise and vehicle problems for city residents. Under the plan, to be debated shortly at the City of Sydney, no buildings – except for owner-occupied constructions or residential renovations – would be approved unless developers agreed to halt work from Saturday through to the end of Tuesday over a long weekend. Labour councillor Verity Firth is leading the push to have the policy adopted, hoping to court the key vote of the Lord Mayor, Clover Moore, who came to power on a stance of appropriate development and heightened controls. Cr Firth urged support for the motion, whose aim is to improve the lives of 140,000 residents who have suffered the side-effect of the recent construction boom. “This plan offers respite to the growing numbers of city residents who are forced to undergo excessive noise and dust from building sites on long weekends when they wish to rest and relax after a hard week at work,” she said. 25

Noise Notes 4-4

30/03/06

8:22 am

Page 26

the beat is getting stronger The correlations show that variations in total A-weighted level near the turbines are correlated with the 1/3 octave band levels with frequencies from 400 through 3150 Hz (where ρ > 0.4), which is trailing edge sound. This is one octave lower (200 - 1600 Hz) for the sound at the façade: the higher frequencies were better absorbed during propagation through the atmosphere. The façade spectra in figure 3C show a local minimum at 50-63 Hz, followed by a local maximum at 80-100 Hz. (In a FFT spectrum minima are at 57 and 170 Hz, maxima at 110 and 220 Hz.) This is caused by interference between the direct sound wave and the wave reflected by the façade at 1.5 m from the microphone: for wave lengths of approx. 6 m (55 Hz) this leads to destructive interference, for wave lengths of 3 m (110 Hz) to constructive interference. In figure 4A the three average spectra at the same locations as in figure 3A-C have been plotted, but now for a total measurement time of approx. 9.5 (façade), 5 (T7) and 6 (T1) minutes. For each of these measurement periods the average of the 5% of samples with the highest broad band A -weighted sound level (i.e. the equivalent spectral level of the LA5 percentile) has also been plotted, as well as the 5% of samples with the lowest broad band level (LA95).

The range in A-weighted broad band level can be defined as the difference between the highest and lowest value: Rbb = LAmax - LAmin. Similarly the range per 1/3 octave or octave band Rf can be defined by the difference in spectral levels corresponding to LAmax and LAmin. The difference between LA5 and LA95 is a more stable value, avoiding possibly incidental extreme values, especially when spectral data are used. Rbb,90 is defined as the difference in level between the 5% highest and the 5% lowest broad band sound levels: Rbb,90 = LA5 - LA95. For spectral data, Rf,90 is the difference between spectral levels associated with LA5 and LA95. Values of Rf,90 are plotted in the lower part of figure 4A (here octave bandlevels have been used to avoid the somewhat ‘jumpy’ behaviour of the 1/3 octave band levels). Close to turbines 1 and 7 Rbb is 4.8 and 4.1 dB, respectively. Rbb,90 is 3.2 and 2.6 dB, which is almost the same as Rf,90 (3.2 and 3.0 dB) at 1000–4000 Hz. Further away, at the façade, Rbb is comparable to the near turbine values: 4.9 dB. Rbb,90 at the façade is 3.3 dB and again almost the same as maximum Rf,90 (3.5 dB) at 1000 Hz. Also, close to the turbine there is a low frequency maximum in R f,90 at 2 (or 8) Hz that is also present at the façade, indicating that the modulation of trailing edge sound is correlated in time with the infrasound caused by the blade movement.

Figure 4B presents similar plots for the average spectra and the LA5 and LA95 spectra at dwelling R and near turbine T16 over a period of 16 minutes. Close to the turbine the broadband Rbb,90 is 3.7 dB; octave band R f,90 is highest (5.1 dB) at 1000 Hz. Near R broad band Rbb,90 is also 3.7 dB, and octave band R f,90 is highest (4.0 dB) at 500 Hz. The Rbb ranges are 2.3–2.5 dB higher than the 90% ranges Rbb,90. A 25 second part of this 16 min period is shown in figure 5. The broad band level LA changes with time at T16 and R, showing a more or less regular variation with a period of approximately 1 s (= 1/fB). In these measurements the infrasound level was lower than in the previous measurements at dwelling P where beating was more pronounced. G-weighted sound level during the 16 minutes at R was 70.4 dB(G), and at T16 77.1 dB(G). Finally figure 3C gives average spectra over a period of 16 minutes at dwelling Z. Rf,90 is now highest (4.8 dB) at 1 kHz, and broadband Rbb,90 is 4.3 dB (Rbb = 5.9 dB). The turbine near Z is smaller and lower, but rotates faster than the Rhede turbines; for a hub height wind speed of 6 m/s the expected calculated increase in trailing edge sound for the lower tip relative to the day time situation is 2.0 ± 0.8 dB for a stable, and 2.9 ± 0.8 dB for a very stable atmosphere. For this turbine a 26

volume 4 number 4

noise notes

30/03/06

8:22 am

Page 27

the beat is getting stronger peak trailing edge sound level is expected (according to equation A2 in appendix) at a frequency of 1550/a Hz ≈ 400 – 800 Hz. In all cases above the measured sound includes ambient background sound. Ambient background sound level could not be determined separately at the same locations because the wind turbine(s) could not be stopped (it has been shown elsewhere that it is a flaw in noise regulation to make independent noise assessment procedurally impossible because of its dependency on wind turbine owner’s consent [34]). However, at audible frequencies it could be ascertained by ear that wind turbine sound was dominant. At infrasound frequencies this could not be ascertained. But if significant ambient sound were present, subtracting it from the measured levels would lead to lower (infrasound) sound levels, which would not change the conclusion, based on the G-weighted level, that measured infrasound must be considered inaudible.

4.4. BEATS CAUSED BY INTERACTION OF SEVERAL WIND TURBINES In the previous section we saw that measured variations in broad band sound level (Rbb) were 4 to 6 dB. Figure 6 presents the time variation of the broad band Aweighted level from the sound level at the façade of dwelling P over a one minute period [2]. In this night stable conditions prevailed (m = 0.45 from the wind speeds in table I). Turbines 12 and 11 are closest at 710 and 750 m, followed by turbines 9 and 14 at 880 and 910 m. Other turbines are more than 1 km distant and have an at least 4 dB lower immission level than the closest turbine has. The sequence in figure 6 begins when the turbine sound is noisy and constant within 2 dB. After some time (at t = 155 s) regular pulses appear with a maximum height of 3 dB, followed by a short period with louder (5 dB) and steeper (rise time up to 23 dB/s) pulses. The pulse frequency is equal to the blade passing frequency. Then (t > 180 s) the pulses become weaker and there is a light increase in wind speed. This was one of the nights where a distinct beat was audible: a period with a distinct beat alternating with a period with a weaker or no beat, repeated more or

55

Broad band level in dB(A)

Noise Notes 4-4

50

45

40 0 Figure 5 noise notes

5

10 15 Time in s

20

25

ENFORCEMENT QUALITY Tampa, Florida, Councilman John Dingfelder said he wanted the city to consider the tougher enforcement of limits on construction noise. City rules prohibit “unreasonable” and “avoidable” construction noise after 6 p.m. Work can start at 7 a.m. weekdays, 8 a.m. Saturdays and 10 a.m. Sundays. “That is violated all the time,” Dingfelder said about hours of construction work. “That is disruptive to families and neighborhoods.” Councilwoman Rose Ferlita said Tampa police needed to do more to enforce noise limits that the city imposed a year ago after some residents and business owners complained about blaring music. In July, police started using noise meters to enforce the rules, but no one has been cited for exceeding the 85decibel limit. “I have repeatedly heard it is not being enforced,” Ferlita said. Major George McNamara said police do measure music volumes, but violators have agreed to turn down music instead of facing penalties that range from a $200 fine to 60 days in jail.

Broad band A-weighted immission sound level near turbine 17 (upper plot) and close to dwelling R (lower plot). volume 4 number 4

27

30/03/06

8:22 am

Page 28

the beat is getting stronger ANOTHER IDLE ORDINANCE State rules are keeping a Lowell Township resident from getting signs to combat noise from truck traffic on M21. Charles Miller asked the Township Board to put up signs prohibiting engine braking noise. But the Michigan Department of Transportation does not allow township signs on state trunk lines unless they can be enforced, and township officials say they cannot enforce an engine braking prohibition. Although the township has a noise ordinance for such things as barking dogs, it has no measuring tools to enforce the ordinance in cases of truck traffic. Board members said they would review the noise ordinance.

Sound level Lp,50 ms in dB(A)

53 51 49 47 130

140

150

160

170

180

190

Time in s

Figure 6

Broad band A-weighted immission sound level at façade of dwelling P.

less during the entire night. The pattern is consistent with three pulse trains of slightly different frequencies [2]. In figure 7 the equivalent 1/3 octave band spectrum at the façade of P has been plotted for the period of the beat (165 < t < 175 s in figure 6, spectra sampled at a rate of 20 s-1), as well as the equivalent spectrum associated with the 5% highest (LA5 = 52.3 dB(A)) and the 5% lowest (LA95 = 47.7 dB(A)) broad band levels and the difference between both. As in the similar spectra in figure 4 we see that the beat corresponds to an increase at frequencies where trailing edge sound dominates: the sound pulses correspond to 1/3 octave band levels between 200 and 1250 Hz and are highest at 800 Hz. In figure 7 also the equivalent 1/3 octave band levels are plotted for the period after beating where the wind was picking up slightly (t > 175 s in figure 6). Here spectral levels above 400 Hz are the same or slightly lower as on average at the time of beating, but at lower frequencies down to 80 Hz (related to in-flow turbulence) levels now are 1 to 2 dB higher. The increase in the ‘more wind’ spectrum at high frequencies (> 2000 Hz) is probably from rustling tree leaves. Figure 8 shows sound spectra for a period with a distinct beat (150 < t < 175 s in figure 6), and a period with a weak or no beat (130 < t < 150 s).

Each spectrum is an FFT of 0.2 Hz line width from broad band A-weighted immission sound pressure level values. The frequencies are therefore modulation, not sound frequencies. The abscissa spans 20 dB. The spectra show that distinct beating is associated with higher total A-weighted levels at the blade passing frequency and its

60

LANDLORDS’ PERIL

L5 Leq

Student tenants in a house in San Luis Obispo were, according to a neighbour, rowdy. So he sued the owner of the house. The judge ruled in his favour, awarding him nearly $4000 dollars – $200 each for 17 documented noise disturbances, plus court fees. According to the judge, the homeowner ‘failed to discharge his obligation as a property owner to neighbouring properties, despite his knowledge of the substantial noise problems created by his tenants.’ 28

1/3 octave band level in dB

Noise Notes 4-4

L95

50

more wind L5-L95

40

8 6 4

30

2 0 20 10

Figure 7

1000 100 1/3 octave band frequency in Hz

−2 10000

1/3 octave band levels at façade of dwelling P during beating (Leq, L10 and L90) and when wind speed is picking un (Leq). volume 4 number 4

noise notes

30/03/06

8:22 am

Page 29

the beat is getting stronger harmonics. As has been shown above, the higher level is related to the frequency range of trailing edge sound, not to infrasound frequencies linked to thickness sound. When beating is weaker but there is more wind (t > 175 s), the level of the odd harmonics (base frequency k = 1, and k = 3) is lower than during ‘beat’, whereas the first two even harmonics (k = 2, 4) are equally loud, indicating more distorted (less sinusoidal) and lower level pulses. It is important to realize that the periodic variation as represented in figure 8 is the result from a wind farm, not from a single turbine. In long term measurements near the Rhede wind farm, where average and percentile sound levels were determined over 5 minute periods, periods where wind turbine sound was dominant could be selected with a criterion (Rbb,90 = LA5 - LA95 ≤ 4 dB) implying a fairly constant source with less than 4 dB variation for 90% of the time [2]. The statistical distribution of the criterion values has been plotted in 1 dB intervals in figure 9 for the two long term measurement locations A and B (see figure 2). Total measurement times –with levels in compliance with the criterionwere 110 and 135 hours, respectively. Relative to dwellings P and R, one location (A, 400 m from nearest turbine) is closer to the turbines, the other (B, 1500 m) is further.

The figure shows that the criterion value (cut off at 4 dB) at both locations peaks at 2.5 dB. Also plotted in figure 9 is the value of LAmax - LAaq (while Rbb,90 ≤ 4 dB), peaking at 3.5 dB at both locations. Finally, the difference between maximum and minimum level within 5 minute periods, LAmax - LAmin = Rbb, peaks at 4.5 dB (location A) and 5.5 dB (B). Where Rbb > 7 dB, the distributions are influenced by louder (non-turbine) sounds, such as from birds. Extrapolation of the distribution from lower values suggests that the maximum range Rbb due to the wind farm is 8.5 dB (location A) to 9.5 dB (B). This is 4 dB more than the most frequently occurring ranges at both locations.

4.5. SUMMARY OF RESULTS In table II the level variations due to blade swish as determined in the previous sections have been summarised. Some values not presented in the text have been added. The ranges are presented as Rbb and Rbb,90. The latter is of course a lower value as it leaves out high and low excursions occurring less than 10% of the time. The time interval over which these level differences occur differ: from several up to

Beat

0,2 Hz band level in dB

Noise Notes 4-4

No beat More wind

0

Figure 8

noise notes

2

4 6 Frequency in Hz

8

10

Sound power spectrum of A-weighted broad band immission sound level at façade of dwelling P when beating is distinctly or not audible and with slightly increased wind speed. volume 4 number 4

29

Noise Notes 4-4

30/03/06

8:22 am

Page 30

the beat is getting stronger 16 minutes for the short term measurements, where wind conditions can be presumed constant, up to over 100 hours at locations A and B.

5. PERCEPTION OF WIND TURBINE SOUND In a review of literature on wind turbine sound Pedersen concluded that wind turbine noise was not studied in sufficient detail to be able to draw general conclusions, but that the available studies indicated that at relatively low levels wind turbine sound was more annoying than other sources of community noise such as traffic [21]. In a field study by Pedersen and Persson Waye [22] 8 of 40 respondents living in dwellings with (calculated) maximum outdoor immission levels of 37.5 - 40.0 dB(A) were very annoyed by the sound, and at levels above 40 dB(A) 9 of 25 respondents were very annoyed. The correlation between sound level (in 2.5 dB classes) and annoyance was significant (p < 0.001). In this field study annoyance was correlated to descriptions of the sound characteristics, most strongly to swishing with a correlation coefficient of 0.72 [22]. A high degree of annoyance is not expected at levels below 40 dB(A), unless the sound has special features such as low-frequency components or an intermittent character [23]. Psychoacoustic characteristics of wind turbine sound have been investigated by Persson-Waye et al.

in a laboratory setting with naive listeners (students not used to wind turbine sound): the most annoying sound recorded from five different turbines were described as ‘swishing’, ‘lapping’ and ‘whistling’, the least annoying as ‘grinding’ and ‘low frequency’ [24]. People living close to wind turbines, interviewed by Pedersen et al., felt irritated because of the intrusion of the wind turbines in their homes and gardens, especially the swishing sound, the blinking shadows and constant rotation [25]. Table II. Level variation in modern wind turbine1 sound due to blade swish, in dB Atmospheric condition

Rbb LAmax – LAmin

Section 3a Section 3a Section 3a

neutral stable very stable (very) stable

1.5 ± 0.5 3.1 ± 0.7 5.0 ± 0.8 single + 3

[8] fig. 2A fig. 2A fig. 2B fig. 2C fig. 2B fig. 2A fig. 5 fig. 6A

unspecified

Near Tl Near T7 Near T16 dwelling Z dwelling R façade dwelling P façade P + beat Location A

<3 4.8 4.1 6.0 5.92 6.2 4.9 5.4 4.5 (most frequent) 8.5 (maximum)

Location B

fig. 6B

Location Calculated results Single turbine

Two turbines Measured results Single turbine Single turbine

Multiple turbines

Reference

stable

Rbb,90 LA5 – LA95

3.2 2.6 3.7 4.3 3.7 3.3

long term, stable 5.5 (most frequent) 9.5 (maximum)

notes: lhub height 100 m, rotor diameter 70 m, 20 rpm 2for this turbine (hub height 45 m, diameter 46 m, 26 rpm) R

30

bb < 3.7 dB was calculated

volume 4 number 4

noise notes

Noise Notes 4-4

30/03/06

8:22 am

Page 31

the beat is getting stronger Our experience at distances of approx. 700 to 1500 m from the Rhede wind farm, with the turbines rotating at high speed in a clear night and pronounced beating audible, is that the sound resembles distant pile driving. When asked to describe the sound of the turbines in this wind farm, a resident compares it to the surf on a rocky coast. Another resident near a set of smaller wind turbines, likens the sound to that of a racing rowing boat (where rowers simultaneously draw, also creating a periodic swish). Several residents near single wind turbines remark that the sound often changing to clapping, thumping or beating when night falls: ‘like a washing machine’. It is common in all descriptions that there is noise (‘like a nearby motorway’, ‘a B747 constantly taking of ’) with a periodic increase superimposed. In all cases the sound acquires this more striking character late in the afternoon or at night, especially in clear nights and downwind from a turbine. Part of the relatively high annoyance level and the characterisation of wind turbine sound as lapping, swishing, clapping or beating may be explained by the increased fluctuation of the sound [2, 21].

Our results in table 2 show that in a stable atmosphere measured fluctuation levels are 4 to 6 dB for single turbines, and in long term measurements (over many 5 minute periods) near the Rhede wind farm fluctuation levels of approx. 5 dB are common but may reach values up to 9 dB. The level difference associated with an amplitude modulation (AM) factor mf is ∆L = 20 log((1+mf)/(1-mf)). The modulation factor mf is the change in sound pressure amplitude due to modulation, relative to the average amplitude. For ∆L < 9 dB a good approximation (±5%) is mf = 0.055 ∆L. Now when ∆L rises from 3 dB, presumably a maximum value for a daytime (unstable or neutral) atmosphere, to 6 dB, mf rises from 17% to 33%. For a maximum value of ∆L = 9 dB, mf is 50%. Fluctuations are perceived as such when the modulation frequencies are less than 20 Hz. Human sensitivity for fluctuations is highest at fmod = 4 Hz, which is the frequency typical for rhythm in music and speech [26], and for frequencies of the modulated sound close to 1 kHz. For wind turbines we found that a typical modulation frequency is 1 Hz, modulating the trailing edge sound that itself is at frequencies of 500 – 1000 Hz. So human sensitivity for wind turbine sound fluctuations is relatively high.

Fluctuation strength can be expressed in a percentage relative to the highest perceptible fluctuation strength (100%) or in the unit vacil [26]. The reference value for the absolute fluctuation strength is 1 vacil, equalling a 60 dB, 1 kHz tone, 100% amplitude-modulated at 4 Hz [26]. For an AM pure tone as well as AM broad band noise, absolute fluctuations strength is zero until ∆L ≈ 3 dB, then increases approximately linearly with modulation depth for values up to 1 vacil. For a broad band noise level LA the fluctuation strength Fbb can be written as [26]:

Fbb =

5.8(1.25mf – 0.25)(0.05L A – 1) ( fmod /5Hz)2 + (4Hz/ fmod ) + 1.5

vacil (2)

With typical values of fmod = 1 Hz and LA = 40 dB(A), this can be written as Fbb = 1.31(mf-0.2) vacil or, when ∆L < 9 dB: Fbb = 0.072 ( ∆L – 3.6)

noise notes

volume 4 number 4

vacil

(3)

31

Noise Notes 4-4

30/03/06

8:22 am

Page 32

the beat is getting stronger When ∆L increases from 3 to 6 dB, Fbb increases from negligible to 0.18 vacil. For the high fluctuation levels found at locations A and B (∆L = 8 – 9 dB), Fbb is 0.32 to 0.39 vacil. It can be concluded that, in a stable atmosphere, the fluctuations in modern wind turbine sound can be readily perceived. However, as yet it is not clear how this relates to possible annoyance. It can however be likened to the rhythmic beat of music: pleasant when the music is appreciated, but distinctly intrusive when the music is unwanted. The hypothesis that these fluctuations are important, is supported by descriptions of the character of wind turbine sound as ‘lapping’, ‘swishing’, ‘clapping’, `beating’ or ‘like the surf ’. Those who visit a wind turbine in daytime will usually not hear this and probably not realise that the sound can be rather different in conditions that do not occur in daytime. This may add to the frustration of residents: “Being highly affected by the wind turbines was hard to explain to people who have not had the experiences themselves and the informants felt that they were not being believed” [25]. Persson-Waye et al. observed that, from five recorded different turbine sounds “the more annoying noises were also paid attention to for a longer time”.

This supported the hypothesis that awareness of the noise and possibly the degree of annoyance depended on the content (of intrusive character) of the sound [24]. Fluctuations with peak levels of 3 – 9 dB above a constant level may have effects on sleep quality. The Dutch Health Council [33] states that “at a given Lnight value, the most unfavourable situation in terms of a particular direct biological effect of night-time noise is not, as might be supposed, one characterised by a few loud noise events per night. Rather, the worst scenario involves a number of noise events all of which are roughly 5 dB(A) above the threshold for the effect in question.” For transportation noise (road, rail, air traffic) the threshold for motility (movement), a direct biological effect having a negative impact on sleep quality, is a sound exposure level per sound event of SEL = 40 dB(A) in the bedroom [33]. The pulses in figure 6 have SEL-values up to 50 dB(A), but were measured on the façade. With an open window facing the wind turbines indoor SEL-values may exceed the threshold level. In other situations this of course depends on distance to and sound power of the turbines and on the attenuation between façade and bedroom.

De tekst is automatisch uit het bestand gehaald en kan afwijken van het origineel (kolommen, tabellen en koppen lopen door elkaar). Het officiële stuk bij de gemeente is leidend. Bron: https://api1.ibabs.eu/publicdownload.aspx?site=Oss&id=72a2139a-7637-4c18-8c6f-871f636672a0