WindGuard Certification GmbH

WtNDGUARD Certincatlon

Oldenburger StraSe 65, 26316 Varel, Germany

PROVISJONAL PROTOTYPE CERTIFICATE No.:ZT21224-PPC.01-R0 *ü

This certificate is issued to

EAZWind Industrieweg 23A 9601 U, Hoogezand The Netherlands

for the wind turbine type

EAZ13.2

wind turbine dass (dass, Standard, year)

swr class IV,1E(»1400-2; Edition 3.0:2013-12

at the specific site

53’18’18.3*N 6M5’37,rE

m

in

This certificate attests compliance with lEC 61400 Series as specified in subsequent pages It is based on the fbllowing reference document; Final Evaluation Report Dated

The confoimity evaluation was carried out in accordance with the rules and procedures of the lEC 61400-22

The wind turbine type specification begins on page 2 of this certificate.

Changes in the system design or the manufactureris quality system are to be approved b^eJSejJ^tion Body. Without approval, the certificate loses its validity.

This oertificate is valid until: 29.11.2023

((DAkkS "V

.

ORjhehi

AUtradMtnntMDile o-rr-i7i95^<io

WindGuard Certification GmbH

WINDGUARD Ceitlflcatlon

Oldenburger StraBe 65, 26316 Varel, Germany

PROVISIONAL PROTOTYPE CERTIFICATE No.: ZT21224-PPC.01-R0

Machine parameters: Power regulation:

Mechanical (passive) pitch

Rotor orientation:

Up-wind

Number of rotor blades;

3

Rotor tilt:

4°

Cone angle:

0

Rated power:

15 kW

Rated wind speed Vr:

7.2 m/s

Rotor diameter:

13.2 m

Hub height(s):

15 m

Hub height operating wind speed range Vin - Vout:

2.5 - 25 m/s

Design life time:

20 years

Software version:

n/a

°

Wind conditions: Characteristic turbulence intensity Irof at Vhub = 15 m/s:

18%

Annual average wind speed at hub height Vave:

6 m/s

Reference wind speed Vref:

30 m/s

Mean flow inclination:

8°

Hub height 50-year extreme wind speed Veso:

42 m/s

Electrical netwerk conditions: Normal supply voltage and range:

480V±10%

Normal supply frequency and range:

50 Hz ± 2%

Voltage imbalance:

2%

Maximum duration of electrical power network outages

24h

Number of electrical network outages

20/y

Issued 30.11.2022

2/3

WindGuard Certification GmbH

WINDGUARD Certification

Oldenburger StraBe 65, 26316 Varel, Germany

PROVISIONAL PROTOTYPE CERTIFICATE No.:ZT21224-PPC.01-R0

Other environmental conditions (where taken into account): Design conditions in case of offshore WT :

n/a

Normal and extreme temperature ranges:

-20°C - +50”C

Relative humidity of the air:

95%

Air density:

1.225 kg/m3

Solar radiation:

1000 W/m2

Lightning protection system (Standard and protection class):

n/a

Earthquake model and parameters (Standard and key

n/a

parameters e.g. spectrum, model, seismic zone, soil class, etc.): Other design conditions :

Corrosion protection is for marine grade

Outstanding issues: • Safety and Function Tests

Issued 30.11.2022

3/3

De tekst is automatisch uit het bestand gehaald en kan afwijken van het origineel (kolommen, tabellen en koppen lopen door elkaar). Het officiële stuk bij de gemeente is leidend. Bron: https://api1.ibabs.eu/publicdownload.aspx?site=middendelfland&id=1f414ff2-a4fc-4525-b323-f759d9382dcf