2.1 Tekening Eendrachtstraat 28, Meppel (plattegrond kelder)
Tekst van het document
01
02
04
6600
8036
05
07
1378
09
9350
10
4128
12
3682
13
7810
9414
50398 100
23838
100
100 1200 100
2395
300
1486
100
26568
100
300
1486
100
26656
100
100
2462
300
1540
214
2000
214
2470
214
300
1540
214
2000
214
2470
214
214
1540
300
214
1540
300
100
2750
1915
100
100
100
1830
2750
100
2193
100
1915
100 1200 100
100
1804
3016
300 300
1804
6306
300 300
300
10630
300
6286
1600
2744
300
P
P
P
P
5,0 m²
5,0 m²
5,0 m²
5,0 m²
P
-1.06 gang
01
05
06
07
08
$
09
46 berging
45 berging
44 berging
43 berging
42 berging
41 berging
5,0 m²
5,0 m²
5,2 m²
5,2 m²
5,0 m²
5,2 m²
5,0 m²
48 berging
49 berging
5,0 m²
5,0 m²
5,0 m²
15
-1.03 trappenhuis 2
4,1 m²
30 berging
31 berging
5,2 m²
5,4 m²
5,4 m²
$
-1.02 parkeergarage
$
-1.04 gang
998,3 m²
13 berging
5,1 m²
14 berging
P
24 berging
17
75,1 m²
300
P
P
P
P
300 2883
P
$
18
19
20
21
22
23
LUCHT- EN WATERDICHTHEID EN VOCHTWERENDE VOORZIENINGEN De uitwendige scheidingsconstructie van een verblijfsgebied, toiletruimte en een badruimte dient waterdicht te zijn uitgevoerd conform NEN 2778. De scheidingsconstructie van een verblijfsgebied, toiletruimte en een badruimte met een kruipruimte dient waterdicht te zijn uitgevoerd conform NEN 2778. De inwendige scheidingsconstructie van een verblijfsgebied niet grenzend aan een ander verblijfsgebied, een toiletruimte en een badruimte dient waterdicht te zijn uitgevoerd conform NEN 2778.
$
C
2500
2500
332
2500
2500
364
2500
2500
332
2500
150
1328
C
150
VENTILATIEVOORZIENINGEN De ventilatievoorzieningen van het gebouw zijn bepaald conform NEN 1087. En voldoen aan de eisen gesteld in het besluit bouwwerken leefomgeving, voor de uitvoering hiervan zie rapport installatieadviseur. Mechanische ventilatie volgens NEN 1087 en NPR 1088. 15863
15863
B
5300
6300
34
150
Rc ≥ 6,3 m²K/W Rc ≥ 6,3 m²K/W Rc ≥ 3,7 m²K/W Rc ≥ 4,7 m²K/W Rc ≥ 4,7 m²K/W U ≤ 1,6 W/m²K | ZTA=0,4 Ud ≤ 1,6 W/m²K | ZTA=0
RENVOOI HEMELWATER-AFVOERSYSTEMEN Plaats en diameter hemelwaterafvoeren volgens nadere berekening installateur. Plaats en afmetingen nood-overstorten volgens nadere berekening constructeur.
P
1000
-1.05 gang
5,0 m²
P
P
5,0 m²
15 berging
RENVOOI WARMTEWEERSTANDEN Isolatiewaarden conform BENG berekening. Daken Vloeren BG boven parkeren Vloeren BG boven bergingen Buitenwanden wanden tussen parkeren-verkeersruimte Kozijnen (glas + kozijn) Deuren
35
5,0 m²
RENVOOI INBRAAKWERENDHEID Deuren, ramen, kozijnen en daarmee gelijk te stellen constructieonderdelen in een scheidingsconstructie van een niet-gemeenschappelijke ruimte die volgens NEN 5087 bereikbaar zijn voor inbraak, hebben een volgens NEN 5096 bepaalde inbraakwerendheid die voldoet aan de in die norm bedoelde weerstandsklasse 2.
36
25 berging
5130
3933
5,0 m²
D
P
23 berging
5,0 m²
2838
1250
300
44,6 m²
D
1250
$
5,0 m²
29 berging
D
15,9 m²
5,0 m²
22 berging
214
300
-1.01b lift
RENVOOI TRAPPEN Trappen volgens artikel 4.24 (aansturingsartikel), tabel 4.24 besluit bouwwerken leefomgeving. Hoofdtrappen: Optrede: 186,8mm. Aantrede: 220mm. Hoogte leuning tov voorkant tredevlak: 900mm. Vluchttrappen: Optrede: 208,8mm. Aantrede: 185mm. Hoogte leuning tov voorkant tredevlak: 900mm.
1230 214
$
75,1 m²
4138
-1.05 gang
RENVOOI CONSTRUCTIES Alle afmetingen van staal-, hout- en/of betonconstructies volgens statische berekeningen constructeur en/of opgave fabrikant. Uiterlijk 3 weken voor aanvang van de bouwwerkzaamheden zijn de constructieve stukken in het bezit van de gemeente.
214
5,0 m²
12 berging
$
214
$
5,0 m²
RENVOOI ALGEMEEN Er zal worden gebouwd conform het besluit bouwwerken leefomgeving en alle van toepassing zijnde NEN- en NPR normen, en eventueel aanvullende eisen van de gemeente.
1250
5,0 m²
38
5,0 m²
28 berging
37
5,1 m²
27 berging
P
11 berging
26 berging
100
E
P
21 berging
100 1820 300
40
16
32798
14
P
37928
13
P
E
300
12
P
39
11
P
6,0 m²
300 1250
P
-1.01a voorportaal lift
300 1250 114
5,3 m²
5,0 m²
214 810 214
2874
P
10
5,1 m²
10 berging
1650 1250 300
P
F
1230
20 berging
214
1250 114 300
300
300
2035 5602
100 1200 100 2167 300
300
5,3 m²
300
5,0 m²
2195 100
51 berging
P
3933
4210
5,1 m²
09 berging
9,8 m²
installatie ruimte
19 berging
E
50 berging
P
100
100
1000
1413
$
100
5,0 m²
08 berging
1754
07 berging
47 berging
300
18 berging
2115 100
15863
51,0 m²
75,1 m²
$
5,0 m²
15863
-1.05 gang
5,0 m²
1754
5,2 m²
-1.06 gang
300
17 berging
100 1200 100
40 berging
06 berging
6300
04
$
9283
100
03
$
5,0 m²
2090
02
5,0 m²
100
16 berging
05 berging
2115 100 2115 100 1200 100 2090 100 2090 100
39 berging
51,0 m²
2090 300 1030 100
6,0 m²
1820
5,0 m²
2280
5,1 m²
38 berging
100
P
37 berging
2883
P
36 berging
5,2 m²
100 2090
P
35 berging
G
100
P
34 berging
100
5,1 m²
33 berging
2650
5,5 m²
32 berging
300
B
5,0 m²
1999 1999 100 1999 100
24928
1999 100 1999 100 1999 100 1999 100 1999 100 2010 300
300
100
10630
5,0 m²
D
1920
2193
300 7,5 m²
100 1999 100
E
100 1250 6150
100
100
300 3630
03 berging
1000
300
300 100
02 berging
04 berging
2090
100 1200 100
2170
1999 100
100
1999 100
01 berging
100 1999
F
4800
1830
100
2193
300
2462
2750
100
2280
100
11581
300
100
2193
100
2462
20006
1830
100
5406
300 100
100
2193
300
2336
100
2280
300
A
G
14920 2243
100 1200 100
2505
23838
100
300
2740
2505
2336
100
2541
1820
300
6331 100
300
300
100 3659
300
2505
300
300
300
RIOLERINGEN EN WATERINSTALLATIES Het gebouw voldoet aan de eisen van rioleringen volgens NEN 3215, NEN 7045 en NEN 7046. Waterinstallaties volgens NEN 1006.
B
WEREN RATTEN EN MUIZEN De uitwendige scheidingsconstructie van het gebouw heeft geen openingen die breder zijn dan 0,01 m 2500
300
2500
300
2500
300
2500
2500
2500
300
4450
P
P
P
P
P
P
P
P
P
3630
P
in- en uitrit auto
C
25
26
27
28
29
30
31
32
RENVOOI BEGLAZING Alle toegepaste beglazing dient te voldoen aan NEN 3569 Veiligheidsbeglazing in gebouwen.
C
RENVOOI ELEKTRICITEITSVOORZIENING De gehele elektrische installatie moet worden uitgevoerd conform NEN 1010
RENVOOI gevelmetselwerk 100mm spouw isolatie, Rc conform BENG-berekening kalkzandsteen, dik 100 / 150 / 214mm
33 300
300
A 300
2505
100 1200 100
300
2505
100
2395
300
2404
300
2336
6217
100
2492
100
B 2490
300
1540
214
2000
214
100 300
2470
214
6150
214
1540
20006 5064
300
5064
2750
300
250
300
5000
300
5000
300
2500
300
2500
5064
300
3828
5500
5130
300
7500
300
4450
300
4214
5000
210
300 2854 3044
9350
1378
06
08
8036
09
7566
2260
12870
11
HJK
13
architecten HJK architecten Laan Corpus den Hoorn 100 9728 JR Groningen 050 3183444 hjk@hjk-architecten.nl www.hjk-architecten.nl
2683
getekend:
Peter van der Veen
schaal:
1 : 100
au
to
project:
inr it
definitief ontwerp
30
51
opdrachtgever:
Actium 25
32
betreft het werk:
Eendrachtstraat in Meppel
onderdeel:
plattegrond kelder
fie ts
04
noodoverstort
rit
03
4128
NO
300
in
02
5222
rookmelder
412
st au elv to ak
01
300
10630
37528 2814
RM
300
300
29464 6600
kooktoestel
300 250 1200
39972 3664
wandtegels
300 300
300 300
250
lichte scheidingswand, dik 100mm A
op
A
300
24
ROOKMELDERS Alle rookmelders moeten worden uitgevoerd conform NEN 2555
300
300
2500
300
300
300
2500
20,3 m²
2500
installatie ruimte
300
in- en uitrit fiets
2500
5130
1000
10430
150
datum:
25-07-2024 BRANDVOORZIENINGEN ≥ 30min WBDBO EI + WtRD Ra & R200 in twee richtingen
revisiedatum
REV
wijziging
30-07-2024
A
brandveiligheidsplan verwerkt op tekening
≥ 30min WBDBO EW + WtRD Ra & R200 in twee richtingen ≥ 60min WBDBO EI + WtRD Ra & R200 in twee richtingen ≥ 60min WBDBO EW + WtRD Ra & R200 in twee richtingen
KOZIJNSYMBOLEN 30 minuten WBD (NEN 6068) 30 minuten WBD (NEN 6068) en zelfsluitend 60 minuten WBD (NEN 6068) 60 minuten WBD (NEN 6068) en zelfsluitend zelfsluitend
$
deur te openen zonder gebruik te maken van losse voorwerpen
Voor brandcompartimentering en brandwerende voorzieningen zie rapport: Brandveiligheidsplan, Munnik Brandadvies BV, d.d. 24-07-2024
vergunningsaanvraag
DO-099