CConstaterende datGoirle
Koppel je AI →
Document · PDF

06 2.9 Bijlage 7 Additionele technische informatie.pdf

Raadsvergadering 4 februari 2025, gemeente GoirleBij agendapunt: 12: Raadsvoorstel Verklaring van geen bedenkingen Zonnepark Beeksedijk AANGENOMEN3.123 woorden

Open het PDF bij iBabs ↗Naar de vergadering →

Tekst van het document

Uit het bestand gehaald, zonder opmaak, tabellen en afbeeldingen

Special for Europe Market

N5

CHSM72N(DG)/F-BH Bifacial Series(182)

560~580W Warranty 12-year Product Warranty

Key Features 30-year Linear Power Warranty

● ● ●

n

● ●

87.40%

●

TOPCon / Half-cut

Low temperature coefficient (Pmpp) Non-destructive cutting PID resistance

Low BOS cost & LCOE Bifacial gain

(years)

xxxxxxxxx

ISO 9001:2015:ISO Quality Management System ISO 14001:2015:ISO Environment Management System ISO 45001:Occupational Health and Safety

2022 TOP Performance

Tier 1

Underwritten by International Insurer

560~580W

0~+5W

POWER RANGE

POWER SORTING

22.5% MAX MODULE EFFICIENCY

Mechanical Specifications Outer dimensions (L x W x H)

2278 x 1134 x 30 mm

No. of cells

144 (6*24)

Front / Back glass

Cable length (Including connector)

n-type mono-crystalline Aluminum, silver anodized

Ground hole

Portrait: ( + )350 mm,( - )250 mm; Customized length

Mounting hole

2.0+2.0 mm

Cable diameter (IEC/UL)

4 mm² / 12 AWG

Connector type (IEC/UL)

HCB40 (Standard) / MC4-EVO2A (Optional)

①

Maximum mechanical test load

5400 Pa (front) / 2400 Pa (back)

Module weight

32.1 kg

Weight of packing unit (for 40'HQ container)

1215 kg

Packing unit

Modules per 40' HQ container

Mounting hole I

36 pcs / box (Subject to sales contract) Drainage hole

648 pcs

① Refer to Astronergy crystalline installation manual or contact technical department. Maximum Mechanical Test Load=1.5×Maximum Mechanical Design Load.

Curve

Electrical Specifications

STC: Irradiance 1000W/m , Cell Temperature 25° C, AM=1.5 2

Rated output (Pmpp / Wp)

560

565

570

575

580

Rated voltage (Vmpp / V)

42.44

42.61

42.77

42.94

43.11

Open circuit voltage (Voc / V)

50.50

50.70

50.90

51.10

51.30

Rated current (Impp /A)

Short circuit current (Isc /A) Module efficiency

YEAR 2-30 POWER DEGRADATION

13.20 13.93

13.26 14.02

B B

Frame technology

≤ 0.4%

FIRST YEAR POWER DEGRADATION

13.33

13.39

14.10

14.19

13.45 14.28

21.7%

21.9%

22.1%

22.3%

22.5%

421.1

424.9

428.6

432.4

436.2

NMOT: Irradiance 800W/m , Ambient Temperature 20° C, AM=1.5, Wind Speed 1m/s

Current-Voltage (570W)

16 14 12

Current (A)

Cell type

≤ 1.0%

10 8 6 4 2 0

10

2

Rated current (Impp /A)

Open circuit voltage (Voc / V) Short circuit current (Isc /A)

39.94

10.54

47.97

11.25

40.10

10.60

48.16

11.32

40.26

40.42

10.65

10.70

48.35

48.54

11.39

Electrical Specifications (Integrated power) Pmpp gain

5%

10%

15%

20%

25%

Pmpp / Wp

Vmpp / V

Impp /A

Voc / V

627

42.77

14.66

50.90

599

656

684

713

42.77

42.78

42.78 42.78

13.99

15.32

15.99 16.65

Electrical characteristics with different rear power gain (reference to 570W)

Temperature Ratings (STC) Temperature coefficient (Pmpp)

-0.29%/℃

Temperature coefficient (Isc)

+0.043%/℃

Nominal module operating temperature (NMOT)

41±2℃

Temperature coefficient (Voc)

-0.25%/℃

11.46

50.90

50.91

50.91 50.91

40.59

10.75

48.73

11.53

30

35

40

45

50

55

35

40

45

50

55

40

45

50

55

Power-Voltage (570W)

600 500 400 300 200

0

Isc /A

14.10

15.48

16.18

16.88 17.58

3

Junction box IP rating

IP 68

Max. system voltage (IEC/UL)

1500VDC

Max. series fuse rating

25

100

Operating Parameters No. of diodes

20

Voltage (V)

Power (W)

Rated voltage (Vmpp / V)

16

10

15

20

25

30

Voltage (V)

Current-Voltage (570W)

14 12

Current (A)

Rated output (Pmpp / Wp)

15

10 8 6 4 2 0

30 A

Cell s temp.=25 Cell s temp.=35 Cell s temp.=45 Cell s temp.=55 Cell s temp.=65

10

15

20

25

30

35

Voltage (V)

© Chint New Energy Technology Co., Ltd. Reserves the right of final interpretation. please contact our company to use the latest version for contract. https://www.astro-energy.com

202304

7

6

5

4

2

3

6.05'

2.43'

E

E

°'

°'

N

D

/

/

/

/

N

/

/

/

/

/

/

/

/

/

/

D

/

betonplaat funderingselement

1.29'

.l,

C

-= -

2.891

.,

� 1

1.50'

1

1'c-, ,;-, --± O'

N

N

1=:=fu -�

_L_

1 1

�-

-

.29'

é,

u, N ,--'

-

é, u,

1

1

\�

-

l 1

49'

- -- 'I

1

�

�,

151,

u

\

1

1

\�

h;,

�v

0

� 'Al

129

.,

: 88 1

,--'

.,...S,

',f!.,; .:.+- i'.n

1

2.28'

150'

- - -

1

1_

1

� 1

150

1

en ,­ ,-

B

sco.le:

� 1

_L_ 1

C

1.50'

i,::::. - - -

1

k] 1 "' ��1xHT DN2

1

.l, 3 ,l,

1

� - co

� _J 2 891

o

1

5 i•

S Y, V -

1

"

,.

"� m-;t

1

1

.,

.,

---r- n

2xHT

11

1

- 1 ,_

LL

DN25

9xHT DN250

1

150'

funderingselement

11

1

+-- ----1- -- �-

�<

u,

1

1

�

6.05'

--�'f.� 1

lso'

l

l betonplaat

-

1

2.28'

l

,

u,

150'

�-

30 .l

=

N

"- �

B

HT DN250

1

49•l

funderingselement

funderingselement

funderingselement

501

-

é, u,

date

customer

�� 129

TPsolar-konzept B.V. 1,, Melbournestraat 9 TP-:... Solar 175 RM Lijnden � •. h

index

revision

name

date

edit draw check

name

drawing number

01.04.2020

Ko

project

01.04.2020

Ko/AB planning state

�

e4r

engineers for renewables

e4r - engineers for renewables GmbH Poststr. 11-12 10178 Berlin T +49 (0) 30 4372 5105 M contact@e-4-r.de a ng ts reserve

A 9.06

Multiplication and dissemination only with permission of e4r 7

6

5

4

3

19-171 EK01 PV power plant Goirle Beeksedijk draft

drawing

station foundation

version

scale

page 1/1

format

1 :50 A3

engineers for renewables GmbH [UrhG §2 (7); §16 2

1

A

MVPS-4000-S2 / MVPS-4200-S2 / MVPS-4400-S2 / MVPS-4600-S2

MV POWER STATION 4000-S2 / 4200-S2 / 4400-S2 / 4600-S2

Robust

• Station and all individual components type-tested • UL Listing • Optimally suited to extreme ambient conditions

Easy to Use

Cost-Effective

Flexible

• Plug and play concept • Completely pre-assembled for easy set-up and commissioning

• Easy planning and installation • Low transport costs due to 20-foot skid

• One product for the whole world • DC-Coupling Ready • Numerous options

MV POWER STATION 4000-S2 / 4200-S2 / 4400-S2 / 4600-S2

Turnkey Solution for PV Power Plants

With the power of the new robust central inverters, the Sunny Central UP or Sunny Central Storage UP, and with perfectly adapted medium-voltage components, the new MV Power Station offers even more power density and is a turnkey solution available worldwide. The solution is the ideal choice for new generation PV power plants operating at 1500 VDC. Delivered pre-configured on a 20-foot High Cube Container Skid, the solution is easy to transport and quick to assemble and commission. The MVPS and all components are type-tested. The UL Listing for the North American market is available. The MV Power Station combines rigorous plant safety with maximum energy yield and minimized deployment and operating risk. The MV Power Station is prepared for DC- Coupling.

MV POWER STATION 4000-S2 / 4200-S2 / 4400-S2 / 4600-S2

Technical Data

MVPS 4000-S2

Input (DC) Available inverters Max. input voltage Max. input current Number of DC inputs Integrated zone monitoring Available DC fuse sizes (per input) Output (AC) on the medium-voltage side Rated power at 1000 m and cos phi = 1 (at -25°C to + 25°C / at 40°C / at 45°C)1) Optional: rated power at 1000 m and cos phi = 1 (at -25°C to +25°C / at 50°C / at 55°C)1) Typical nominal AC voltages AC power frequency Transformer vector group Dy11 / YNd11 / YNy0 Transformer cooling methods Max. output current at 33 kV Transformer no-load losses Standard / Ecodesign at 33 kV Transformer short-circuit losses Standard / Ecodesign at 33 kV Max. total harmonic distortion Reactive power feed-in (up to 60% of nominal power) Power factor at rated power / displacement power factor adjustable Inverter efficiency Max. efficiency3) / European efficiency3) / CEC weighted efficiency4) Protective devices Input-side disconnection point Output-side disconnection point DC overvoltage protection Galvanic isolation Internal arc classification medium-voltage control room (according to IEC 62271-202) General Data Dimensions equal to 20-foot HC shipping container (W / H / D) Weight Self-consumption (max.

/ partial load / average)1) Self-consumption (stand-by)1) Degree of protection according to IEC 60529 Environment: standard / harsh Degree of protection according to IEC 60721-3-4 (4C1, 4S2 / 4C2, 4S4) Maximum permissible value for relative humidity Max. operating altitude above mean sea level 1000 m / 2000 m Fresh air consumption of inverter Features DC terminal AC connection Tap changer for MV-transformer: without / with Shield winding for MV-Transformer: without / with Monitoring package Station enclosure color Transformer for external loads: without / 10 / 20 / 30 / 40 / 50 / 60 kVA Medium-voltage switchgear: without / 3 feeders 2 cable feeders with load-break switch, 1 transformer feeder with circuit breaker, internal arc classification IAC A FL 20 kA 1 s according to IEC 62271-200 Short circuit rating medium voltage switchgear (20 kA 1 s / 20 kA 3 s / 25 kA 1s) Accessories for medium-voltage switchgear: without / auxiliary contacts / motor for transformer feeder / cascade control / monitoring Integrated oil containment: without / with Industry standards (for other standards see the inverter datasheet) ● Standard features Type designation

○ Optional features

— Not available

MVPS 4200-S2

1 x SC 4000 UP (-US) or 1 x SC 4200 UP (-US) or 1 x SCS 3450 UP (-US) 1 x SCS 3600 UP (-US) 1500 V 1500 V 4750 A 4750 A 24 double pole fused (32 single pole fused) ○ 200 A, 250 A, 315 A, 350 A, 400 A, 450 A, 500 A 4000 kVA / 3400 kVA / 0 kVA 4000 kVA / 3400 kVA / 0 kVA 11 kV to 35 kV 50 Hz / 60 Hz ●/○/○ KNAN2) 70 A 4.0 kW / 3.1 kW 40.0 kW / 29.5 kW

4200 kVA / 3570 kVA / 0 kVA 4200 kVA / 3570 kVA / 0 kVA 11 kV to 35 kV 50 Hz / 60 Hz ●/○/○ KNAN2) 74 A 4.2 kW / 3.1 kW 41.0 kW / 32.5 kW

98.7% / 98.6% / 98.5%

98.7% / 98.6% / 98.5%

< 3% ○ 1 / 0.8 overexcited to 0.8 underexcited

DC load-break switch Medium-voltage vacuum circuit breaker Surge arrester type I ● IAC A 20 kA 1 s 6058 mm / 2896 mm / 2438 mm < 18 t < 8.1 kW / < 1.8 kW / < 2.0 kW < 370 W Control rooms IP23D, inverter electronics IP54 ●/○ ●/○ 95% (for 2 months/year) ●/○ 6500 m³/h Terminal lug Outer-cone angle plug ●/○ ●/○ ○ RAL 7004 ●/○/○/○/○/○/○ ●/○ ●/○/○ ●/○/○/○/○ ●/○ IEC 60076, IEC 62271-200, IEC 62271-202, EN50588-1 IEEE C37.100.1, IEEE C57.12, UL 1741 listed, CSC Certificate MVPS-4000-S2 (-US)

MVPS-4200-S2 (-US)

1) Data based on inverter 2) KNAN = Ester with natural air cooling 3) Efficiency measured at inverter without internal power supply 4) Efficiency measured at inverter with internal power supply

Technical Data

MVPS 4400-S2

Input (DC) Available inverters Max. input voltage Max. input current Number of DC inputs Integrated zone monitoring Available DC fuse sizes (per input) Output (AC) on the medium-voltage side Rated power at 1000 m and cos phi = 1 (at -25°C to + 25°C / at 40°C / at 45°C)1) Optional: rated power at 1000 m and cos phi = 1 (at -25°C to +25°C / at 50°C / at 55°C)1) Typical nominal AC voltages AC power frequency Transformer vector group Dy11 / YNd11 / YNy0 Transformer cooling methods Max. output current at 33 kV Transformer no-load losses Standard / Ecodesign at 33 kV Transformer short-circuit losses Standard / Ecodesign at 33 kV Max. total harmonic distortion Reactive power feed-in (up to 60% of nominal power) Power factor at rated power / displacement power factor adjustable Inverter efficiency Max. efficiency3) / European efficiency3) / CEC weighted efficiency4) Protective devices Input-side disconnection point Output-side disconnection point DC overvoltage protection Galvanic isolation Internal arc classification medium-voltage control room (according to IEC 62271-202) General Data Dimensions equal to 20-foot HC shipping container (W / H / D) Weight Self-consumption (max.

/ partial load / average)1) Self-consumption (stand-by)1) Degree of protection according to IEC 60529 Environment: standard / harsh Degree of protection according to IEC 60721-3-4 (4C1, 4S2 / 4C2, 4S4) Maximum permissible value for relative humidity Max. operating altitude above mean sea level 1000 m / 2000 m Fresh air consumption of inverter Features DC terminal AC connection Tap changer for MV-transformer: without / with Shield winding for MV-Transformer: without / with Monitoring package Station enclosure color Transformer for external loads: without / 10 / 20 / 30 / 40 / 50 / 60 kVA Medium-voltage switchgear: without / 3 feeders 2 cable feeders with load-break switch, 1 transformer feeder with circuit breaker, internal arc classification IAC A FL 20 kA 1 s according to IEC 62271-200 Short circuit rating medium voltage switchgear (20 kA 1 s / 20 kA 3 s / 25 kA 1s) Accessories for medium-voltage switchgear: without / auxiliary contacts / motor for transformer feeder / cascade control / monitoring Integrated oil containment: without / with Industry standards (for other standards see the inverter datasheet) ● Standard features Type designation

○ Optional features

— Not available

MVPS 4600-S2

1 x SC 4400 UP (-US) or 1 x SC 4600 UP (-US) or 1 x SCS 3800 UP (-US) 1 x SCS 3950 UP (-US) 1500 V 1500 V 4750 A 4750 A 24 double pole fused (32 single pole fused) ○ 200 A, 250 A, 315 A, 350 A, 400 A, 450 A, 500 A 4400 kVA / 3740 kVA / 0 kVA 4400 kVA / 3740 kVA / 0 kVA 11 kV to 35 kV 50 Hz / 60 Hz ●/○/○ KNAN2) 77 A 4.4 kW / 3.1 kW 42.0 kW / 35.7 kW

4600 kVA / 3910 kVA / 0 kVA 4600 kVA / 3910 kVA / 0 kVA 11 kV to 35 kV 50 Hz / 60 Hz ●/○/○ KNAN2) 81 A 4.6 kW / 3.1 kW 43.0 kW / 38.0 kW

98.7% / 98.6% / 98.5%

98.7% / 98.6% / 98.5%

< 3% ○ 1 / 0.8 overexcited to 0.8 underexcited

DC load-break switch Medium-voltage vacuum circuit breaker Surge arrester type I ● IAC A 20 kA 1 s 6058 mm / 2896 mm / 2438 mm < 18 t < 8.1 kW / < 1.8 kW / < 2.0 kW < 370 W Control rooms IP23D, inverter electronics IP54 ●/○ ●/○ 95% (for 2 months/year) ●/○ 6500 m³/h Terminal lug Outer-cone angle plug ●/○ ●/○ ○ RAL 7004 ●/○/○/○/○/○/○ ●/○ ●/○/○ ●/○/○/○/○ ●/○ IEC 60076, IEC 62271-200, IEC 62271-202, EN50588-1 IEEE C37.100.1, IEEE C57.12, UL 1741 listed, CSC Certificate MVPS-4400-S2 (-US)

MVPS-4600-S2 (-US)

www.SMA-Solar.com

SMA Solar Technology

MVPS-S2-SC-UP-DS-en-10 SMA and Sunny Central are registered trademarks of SMA Solar Technology AG. FSC-certified paper. Changes to products and services, including those resulting from country-specific requirements, and deviations from technical data are subject to change without notice. SMA assumes no liability for mistakes or printing errors. For the latest information, please visit SMA-Solar.com.

System diagram with Sunny Central UP

.,

�

........ ....

...

ESS Container 5,015 MWh

:r. ::c

2 3:

"'r-

Liquid-cooled battery storage system based on prismatic LFP cells with very high cyclic lifetime

GENERAL

0 n

□

"' .

MECHANICAL

Battery Type

HiTHIUM LFP314-2P52S

Dimensions (L x W x H)

6.058 x 2.438 x 2.896 mm

No. of Battery Modules

48 (6 X 8)

Weight Container (20 ft.)

< 42.000 kg

Configuration

6*2P416S

Protection Level

IP 55

Cooling Method

Liquid Cooling

BMS Communication

CAN, RS485, Ethernet

TEMPERATURE RANGE

Gravimetrie

2: 119 Wh/kg

Operating

Volumetrie

2: 117 Wh/L

Storing (recommended)

Application Altitude

� 4.000 m

-30 °C ... 55 °C 3 -20 °C ... 35 °C 3

PRODUCT CERTIFICATIONS ELECTRICAL Nominal Voltage Container

IEC 62619, IEC 62477, IEC 63056, IEC 61000, UL 1973, UL 9540A, NFPA 855

Safe Transportation

UN 38.3

1.331,2 V

Operating Voltage Container 1.040 ...1.500V Nominal Energy Container

5.015,96 kWh 1• 2

Nominal SOC at delivery

27% 2

Nominal Charge/Discharge 0,5 P / 0,5 P Rate Round Trip Efficiency

Certificates and Reports

>94%

ENVIRONMENTAL Compliance

RoHS, REACH, Cobalt free

Battery Regulation (EU)

2023/1542

1 0,5 P/0,5 P 2 25'C +/- 2,0 3

ambient temperature

COMPANY CERTIFICATIONS ISO 9001, ISO 14001, ISO 45001, SA 8000

HiTHIUM Energy Storage Technology Deutschland GmbH

Website: https://hithium.com I Email: Contact@hithium.de Address: Landsberger Str. 155, 80687 Munich, Germany

Xiamen HiTHIUM Energy Storage Technology Co., Ltd. Address: HiTHIUM lndustrial Park, Tongxiang High Tech Zone, Xiamen, Fujian, China I Email: hithium@hithium.com

■ a "'=

�

l!I . ._· Linkedln

Website

•

Document is subject to regular updates, corrections, and improvements. Kindly check you are using latest version. Picture lor illustration purpose only. Hithium_DS_ESS Container_507 5kWh_Datasheet_20240517_V3.7_EU

A

B

C

D

E

F

G

H

Electric Wire

13

2000

15

14

13

Illustration Eco-Friendly Fence

14

200

12

12

100

I

15

11

11

10

10

9

9

3000

8

8

130

6

Changing

Date

5

Name

Draw

700

4

15.3.2020

Date

HF

Name

3

7

6

5

4

3

Optie 1

2

1

Page

1/1

2

1

All Rights Reserved ©

A4

Format

1:40

Scale

Version

Plan View

Security Fence Example

Drawing

Basic Design

PV Plant Goirle Beeksedijk Planning State

Project

Drawing Number

This document can only be shared or published with the permission of TPSolar-Konzept B.V.

ind.

TP Solar-Konzept B.V Melbournestraat 9 1175 RM Lijnden

Customer

7

2300

A

B

C

D

E

F

G

H

I

Impressie hekwerk Zonnepark Transberg in Dordrecht

Optie 2

Hekwerkdoorgangen voor dassen en ander kleinwild Er zijn diersoorten die zich niet laten stoppen door een gaashekwerk, zij graven er gewoon onderdoor. Soorten zoals dassen, kleine marterachtigen en egels doen dat niet. Zij leven echter wel van wat ze op het land vinden en zouden dus gehinderd worden als ze het zonnepark niet op en af kunnen doordat er hekwerk omheen staat. Voor deze soorten willen de initiatiefnemers regelmatig (elke 75-100 meter) een doorgang in het hekwerk maken. Ter plaatse zal de buis voor het hekwerk op de grond op ca. 20 cm van een paal gemonteerd worden. Dit zorgt ervoor dat het zonnepark Beeksedijk toegankelijk zal zijn voor verschillende diersoorten.

Figuur 1: Faunapassage in hekwerk

Figuur 1: Vooraanzicht

Figuur 2: Zij-aanzicht

Prototype 1.0 (90x90 cm)

Materiaal: Western Red Cedar, onbehandeld (alleen geschaafd)

Bouwtekening

TPSolar Bijenhotel 1.0

Vulling

Paalbevestiging

Prototype bijenhotel bij het zonnepark van TPSolar in Dordecht

Gaasbevestiging

Details prototype 1.0

Zijaanzicht

Gevuld bijenhotel

Vooraanzicht

De tekst is automatisch uit het bestand gehaald en kan afwijken van het origineel (kolommen, tabellen en koppen lopen door elkaar). Het officiële stuk bij iBabs is leidend. Bron: https://raad.goirle.nl/api/v1/meetings/1832/documents/28754