RIS321990 Bijlage 12 Geluidonderzoek omroepinstallaties Escher Gardens
Tekst van het document
Audio & Acoustics Consulting In der Linen 21 52134 Herzogenrath-Kohlscheid Germany
Test engineer:
Oliver Strauch Test Engineer
Reporting engineer
Approved:
Prof. Dr. Anselm Goertz Senior Test Engineer
© by A.Goertz Audio & Acoustics Consulting
File: Elomet-X-6.doc
12/12/2008 11:40
Elomet ; X-6
Page 3 of 13
Measurement equipment and conditions Class-1 semi anechoic chamber (above 100 Hz) (net dimensions: width x length x height: 6 m x 10 m x 5 m) B&K 2610 preamplifier with B&K 4190 1/2” and B&K 4165 1/4” condenser microphones Loudspeaker-Microphone distance: 8 m MF-Software with Robo Frontend and RME Multiface -
24-Bit/96kHz eight channel analogue/digital in/out
-
110 dB S/N ratio
-
Sweep and MLS measurements
-
Highest frequency resolution up to 0,01 Hz linear at 96 kHz SR
Crown Reference I power amplifier Stepper machine: -
up to 100 kg maximum loudspeaker weight
-
up to1,4 m maximum diagonal loudspeaker dimension
-
high precision drive unit up to 1° resolution
-
Data acquisition in EASE, EASE-Focus, EASE Speaker-Lab GLL Ulysses UNF, CLF, SPK raw data and other formats
Technical Equipment (left) and anechoic chamber (right) with stepper machine to move the speakers for balloon and polar measurements.
© by A.Goertz Audio & Acoustics Consulting
File: Elomet-X-6.doc
12/12/2008 11:40
Elomet ; X-6
Page 4 of 13
TABLE OF CONTENTS
1.
AMPLITUDE - FREQUENCY RESPONSE.....................................................................5
2.
PHASE - FREQUENCY RESPONSE................................................................................5
3.
SPECTROGRAM .................................................................................................................6
4.
MAXIMUM SPL ...................................................................................................................6
5.
IMPEDANCE AMPLITUDE...............................................................................................7
6.
IMPEDANCE PHASE..........................................................................................................7
7.
ISOBARS (HORIZONTAL) ................................................................................................8
8.
ISOBARS (VERTICAL).......................................................................................................8
9.
DIRECTIVITY STATISTICS (HORIZONTAL) ..............................................................9
10.
DIRECTIVITY STATISTICS (VERTICAL) ..............................................................10
11.
HORIZONTAL OFF-AXIS FREQUENCY RESPONSES.........................................11
12.
VERTICAL OFF-AXIS FREQUENCY RESPONSES ...............................................11
13.
DATA SHEET .................................................................................................................12
14.
FILE LIST .......................................................................................................................13
© by A.Goertz Audio & Acoustics Consulting
File: Elomet-X-6.doc
12/12/2008 11:40
Elomet ; X-6
1.
Page 5 of 13
Amplitude Frequency Response
x-Axis: Frequency [Hz] y-Axis: Sensitivity [dB SPL] Sensitivity calculated for 1W/1m corresponding to 87,7Veff/1m Free Field 4π conditions ! No frequency smoothing ! Measuring Distance Loudspeaker to Microphone: 8 m Average Sensitivity 300 Hz to 3 kHz: 101,4 dB Frequency Response (-10 dB): 213 Hz – 4,8 kHz Blue Line (-10 dB shifted): 1/3 Oct. frequency smoothing
2.
Graphics-File: X6-FRE.PCX
Phase Frequency Response
x-Axis: Frequency [Hz] y-Axis: Phase [Deg°] 206 at low frequencies: 76 Hz Measuring Distance Loudspeaker to Microphone: 8 m (group delay due to the measurement distance is eliminated for the phase plot)
Graphics-File: X6-PHA.PCX
© by A.Goertz Audio & Acoustics Consulting
File: Elomet-X-6.doc
12/12/2008 11:40
Elomet ; X-6
3.
Page 6 of 13
Spectrogram
x-Axis: Frequency [Hz] y-Axis: Time [ms] z-Axis: Level [dB] 4k FFT length 90% Tukey time window
Graphics-File: X6-ZER.PCX
4.
Maximum SPL
x-Axis: Frequency [Hz] y-Axis: Max.SPL dB @ 1m red line: calculated for maximum power: 1,3 W (=100V)
Average maximum SPL 300 Hz- 3 kHz: 101,7 dB
Graphics-File: X6-MAX.PCX
© by A.Goertz Audio & Acoustics Consulting
File: Elomet-X-6.doc
12/12/2008 11:40
Elomet ; X-6
5.
Page 7 of 13
Impedance Amplitude
x-Axis: Frequency [Hz] y-Axis: Impedance [Ohm] Nominal Impedance: 7,7 kOhm Minimum Impedance: 7,17 kOhm Minimum of 7,17 kOhm at 667 Hz for a rated operating frequency range from 100 Hz to 20 kHz
Graphics-File: X6-IPA.PCX
6.
Impedance Phase
x-Axis: Frequency [Hz] y-Axis: Phase [Deg°]
Graphics-File: X6-IPP.PCX
© by A.Goertz Audio & Acoustics Consulting
File: Elomet-X-6.doc
12/12/2008 11:40
Elomet ; X-6
7.
Page 8 of 13
Isobars (horizontal)
x-Axis: Frequency [Hz] y-Axis: Angle [Deg°] Isobars calculated in relation to on-axis response at 0° Frequency smoothing: 1/3 octave Angle resolution: 5° -6 dB from yellow to light green Measuring Distance Loudspeaker to Microphone: 8 m
Graphics-File: X6-ISO-HOR.PCX
8.
Isobars (vertical)
x-Axis: Frequency [Hz] y-Axis: Angle [Deg°] Isobars calculated in relation to on-axis response at 0° Frequency smoothing: 1/3 octave Angle resolution: 5° -6 dB from yellow to light green Measuring Distance Loudspeaker to Microphone: 8 m
Graphics-File: X6-ISO-VER.PCX
© by A.Goertz Audio & Acoustics Consulting
File: Elomet-X-6.doc
12/12/2008 11:40
Elomet ; X-6
9.
Page 9 of 13
Directivity Statistics (horizontal)
x-Axis: Frequency [Hz] y-Axis: Angle [Deg°] Isobars calculated in relation to on-axis response at 0° Frequency smoothing: 1/3 octave Angle resolution: 5° yellow line: -3 dB isobars yellow line dotted: -3 dB average red line: red line dotted:
-6 dB isobars -6 dB average
green line: green line dotted:
-10 dB isobars -10 dB average
Graphics-File: X6-STAT-HOR.PCX
Averages calculated from 315 Hz to 6,3 kHz Measuring Distance Loudspeaker to Microphone: 8 m
315 Hz ... 6349 Hz -180° ... +180° 0° ... +180° 0° ... -180° Unsymmetry -180° ... +180° 0° ... +180° 0° ... -180° Unsymmetry -180° ... +180° 0° ... +180° 0° ... -180° Unsymmetry -180° ... +180° 0° ... +180° 0° ... -180° Unsymmetry
Limit
Average
STDEV
Maximum
Minimum
-3 -3 -3 -3 -6 -6 -6 -6 -10 -10 -10 -10 -20 -20 -20 -20
103,8 51,9 -51,9 0 168,2 84,1 -84,1 0 235,4 117,7 -117,7 0 300 165,6 -134,3 31,3
36 18 18 0 70,2 35,1 35,1 0 80,9 40,4 40,4 0 90,2 20,7 71,5 54,4
176 88 -17,5 0 360 180 -29,6 0 360 180 -60,6 0 360 180 239,5 345,5
35 17,5 -88 0 59,2 29,6 -180 0 121,2 60,6 -180 0 -133,5 106 -180 0
© by A.Goertz Audio & Acoustics Consulting
File: Elomet-X-6.doc
12/12/2008 11:40
Elomet ; X-6
10.
Page 10 of 13
Directivity Statistics (vertical)
x-Axis: Frequency [Hz] y-Axis: Angle [Deg°] Isobars calculated in relation to on-axis response at 0° Frequency smoothing: 1/3 octave Angle resolution: 5° yellow line: -3 dB isobars yellow line dotted: -3 dB average red line: red line dotted:
-6 dB isobars -6 dB average
green line: green line dotted:
-10 dB isobars -10 dB average
Graphics-File: X6-STAT-VER.PCX
Averages calculated from 315 Hz to 6,3 kHz Measuring Distance Loudspeaker to Microphone: 8 m
315 Hz ... 6349 Hz -180° ... +180° 0° ... +180° 0° ... -180° Unsymmetry -180° ... +180° 0° ... +180° 0° ... -180° Unsymmetry -180° ... +180° 0° ... +180° 0° ... -180° Unsymmetry -180° ... +180° 0° ... +180° 0° ... -180° Unsymmetry
Limit
Average
STDEV
Maximum
Minimum
-3 -3 -3 -3 -6 -6 -6 -6 -10 -10 -10 -10 -20 -20 -20 -20
21,4 10,7 -10,7 0 32,1 16,1 -16,1 0 56,6 28,3 -28,3 0 164,6 101,2 -63,4 37,8
14,2 7,1 7,1 0 21,6 10,8 10,8 0 51,5 25,7 25,7 0 125,8 53,9 74,3 32,2
58,4 29,2 -3,9 0 83,2 41,6 -6,7 0 224 112 -8,9 0 360 180 85,5 175,5
7,8 3,9 -29,2 0 13,4 6,7 -41,6 0 17,8 8,9 -112 0 -44,7 25,6 -180 0
© by A.Goertz Audio & Acoustics Consulting
File: Elomet-X-6.doc
12/12/2008 11:40
Elomet ; X-6
11.
Page 11 of 13
Horizontal Off-Axis Frequency Responses
x-Axis: Frequency [Hz] y-Axis: SPL dB 1W/1m 1/3 Oct. frequency smoothing lines: dotted lines:
0..+90° 0..-90°
Graphics-File: X6-FRE-HOR.PCX
12.
Vertical Off-Axis Frequency Responses
x-Axis: Frequency [Hz] y-Axis: SPL dB 1W/1m 1/3 Oct. frequency smoothing lines: dotted lines:
0..+90° 0..-90°
Graphics-File: X6-FRE-VER.PCX
All PCX graphics files from part 1. to 12. are packed in a Zip-File called: ELOMET-X6-PCX.ZIP © by A.Goertz Audio & Acoustics Consulting
File: Elomet-X-6.doc
12/12/2008 11:40
Elomet ; X-6
13.
Page 12 of 13
Data Sheet Manufacturer
Elomet
Model
X6
Type
100V Column Speaker PN = 1,3 Watt !!
Dimensions (H x W x D) Net Weight Rated Impedance
906 x 164 x 95 mm 7,9 kg 7,7 kOhm
Minimum Impedance
7,17 kOhm @ 667 Hz
Sensitivity (1W/1m)
101,4 dB (300 Hz – 3 kHz)
Frequency Range (-10 dB)
213 Hz – 4,8 kHz
Coverage Pattern (horizontal)
168° (300–6 kHz)
Coverage Pattern (vertical)
32° (300–6 kHz)
Horn rotatable
no
Directivity Factor (Q)
12,6 (300–6 kHz)
Directivity Index (DI)
11 dB (300–6 kHz)
Maximum power RMS / Program / Peak Maximum SPL (continuous program)
© by A.Goertz Audio & Acoustics Consulting
100V / 1,3 Watts 101,7 dB
File: Elomet-X-6.doc
12/12/2008 11:40
Elomet ; X-6
14. Files:
Page 13 of 13
File List ELOMET-X6-PCX.ZIP
all pcx graphics from part 1.-12.
ELOMET-X6.GSS
one EASE Generic Sound Source file
ELOMET-X6-EASE40.ZIP
four EASE40 speaker base files
ELOMET-X6.USB
one Ulysses speaker builder file
ELOMET-X-6.CF1
one CLF1 format binary speaker file
ELOMET-X-6.CF2
one CLF2 format binary speaker file
© by A.Goertz Audio & Acoustics Consulting
File: Elomet-X-6.doc
12/12/2008 11:40
Geluidonderzoek Bp Escher Gardens, Den Haag
Bijlage 4 Titel
Informatie over gebruik omroepinstallatie
Wim Wigerink | DGMR Van: Verzonden: Aan: CC: Onderwerp: Bijlagen:
Blink van den, Ariene TA <Ariene.vandenBlink@NS.NL> dinsdag 14 november 2023 11:36 Wim Wigerink | DGMR Bogels, Maaike M FW: Informatie omroepinstallatie op station Den Haag HS GV omroepbelasting.docx; GV percentage omroepdruk per week.xlsx
U ontvangt niet vaak e-mail van ariene.vandenblink@ns.nl. Meer informatie over waarom dit belangrijk is
Beste Wim, Eerst nu in de gelegenheid jullie van antwoord te voorzien en hopelijk zijn de meegeleverde gegevens van nut. We hebben helaas geen dataset op omroepbericht niveau. Wel hebben we wat screenshots kunnen maken van een dashboard (bestand GV omroepbelasting, dit is 24 uur). Daarnaast nog percentage omroepdruk op weekniveau (bestand GV percentage omroepdruk per week). GV is de spoorse afkorting van Den Haag Hollands Spoor. We hopen jullie hiermee toch enigszins van dienst te zijn. Hartelijke groet, Ariene van den Blink Contractmanager Reisinformatie Servicemanager DCRI
Mobiel: 06 23241538 Secretariaat: 088 6713637 NS | Besturing Operatie | Reisbegeleiding Laan van Puntenburg 100 – 3e verdieping Postbus 2020, 3500 HA Utrecht
Van: Wim Wigerink | DGMR <WWI@dgmr.nl> Verzonden: maandag 9 oktober 2023 16:12 Aan: Reisinformatie.DCRI <Reisinformatie.DCRI@ns.nl> Onderwerp: Informatie omroepinstallatie op station Den Haag HS Goedemiddag, Voor een nieuwbouwproject op korte afstand van treinstation Den Haag Hollands Spoor moeten wij een geluidonderzoek uitvoeren. Hiervoor zijn we op zoek naar informatie over het gebruik van de omroepinstallatie op de perrons. Wij moeten een zo goed mogelijk inschatting maken over het aantal keren dat er berichten worden omgeroepen. In rapporten van andere stations lees ik dat deze informatie door de NS wordt bijgehouden en verstrekt.
1
Ben ik bij u aan het goede adres en zo niet kunt u mij in contact brengen met een persoon/organisatie die deze informatie wel kan verstrekken? Wat we nodig hebben: We willen graag weten wanneer de omroepen plaatsvinden, liefst onderverdeeld in de dag (van 07.00-19.00 uur), de avond (van 19.00 tot 23.00 uur) en tot slot tijdens de nacht (van 23.00 uur tot 07.00 uur). Als er logboeken beschikbaar zijn van een langere periode, bijvoorbeeld het laatste (half)jaar dan zou dat helemaal mooi zijn. Wellicht is er ook nog iets te zeggen over de gemiddelde duur van de berichten. Online vind ik waarden van 20 à 30 seconden per bericht. Ik hoor graag van u of ik aan het goede adres ben. Met vriendelijke groet, W.J. (Wim) Wigerink Senior Adviseur Milieu Gebiedsontwikkeling (Op vrijdagmiddag ben ik niet aanwezig)
Adviseurs voor bouw, industrie, verkeer, milieu en software Weerdjesstraat 70, 6811 JE Arnhem| Postbus 153, 6800 AD Arnhem T 088 346 78 25|M 06 13 25 51 91| E wwi@dgmr.nl| I www.dgmr.nl Wij zoeken nieuwe collega’s! Check onze vacatures
Dit bericht is vertrouwelijk en uitsluitend bestemd voor de geadresseerde. Bent u niet de beoogde ontvanger? Wilt u zo vriendelijk zijn dit direct bij de afzender aan te geven? Ook vragen we u het bericht niet te gebruiken of te publiceren, maar permanent te verwijderen. This message is confidential and intended for the addressee only. Are you not the intended recipient? Would you be so kind as to indicate this directly to the sender? We also ask you not to use or publish the message but to delete it permanently.
Deze e-mail, inclusief eventuele bijlagen, is uitsluitend bestemd voor (gebruik door) de geadresseerde. De e-mail kan persoonlijke of vertrouwelijke informatie bevatten. Openbaarmaking, vermenigvuldiging, verspreiding en/of verstrekking van (de inhoud van) deze email (en eventuele bijlagen) aan derden is uitdrukkelijk niet toegestaan. Indien u niet de bedoelde geadresseerde bent, wordt u vriendelijk verzocht degene die de e-mail verzond hiervan direct op de hoogte te brengen en de e-mail (en eventuele bijlagen) te vernietigen. Informatie vennootschap
2
Hierbij nog een visuele weergave over de afgelopen 24 uur, om inzicht te krijgen in de omroepbelas ng binnen de dag
Deze verdeling hebben we overgenomen in het akoes sch onderzoek
11-17 oktober (aantal omroepen per uur)
11-17 oktober (aantal omroepen per dag)
3 – 17 oktober (aantal omroepen per dag)
-
Gemiddelde omroepduur is rond de 30-35 seconden.
Week heeft minuten
10080
2023-10-16 tot 2023-10-22 stationCode BEHANDELAAR BEHEERDER ERNSTIGE_VERSTORING EVENEMENT_TREIN GEPLANDE_WIJZIGING STATIONBLOKKADE VERTREKKENDE_TREIN VRIJE_TEKST totaleOmroepBelastingInSeconden totaleOmroepBelastingInMinuten Restminuten van de week omroepbelastingInPercent aandeelBehandelaarAanOmroepBelastingInPercent aandeelBeheerderAanOmroepBelastingInPercent aandeelErnstigeVerstoringAanOmroepBelastingInPercent aandeelEvenementTreinAanOmroepBelastingInPercent aandeelGeplandeWijzigingAanOmroepBelastingInPercent aandeelStationBlokkadeAanOmroepBelastingInPercent aandeelVertrekkendeTreinAanOmroepBelastingInPercent aandeelVrijeTekstAanOmroepBelastingInPercent
GV 0 0 2060,53 0 19165,97 0 15442,48 0 36668,98 611,15 9468,85 606,00% 0,00% 0,00% 561,93% 0,00% 5226,75% 0,00% 4211,32% 0,00%
2023-10-09 tot 2023-10-15 stationCode BEHANDELAAR BEHEERDER ERNSTIGE_VERSTORING EVENEMENT_TREIN GEPLANDE_WIJZIGING STATIONBLOKKADE VERTREKKENDE_TREIN VRIJE_TEKST totaleOmroepBelastingInSeconden totaleOmroepBelastingInMinuten Restminuten van de week omroepbelastingInPercent aandeelBehandelaarAanOmroepBelastingInPercent aandeelBeheerderAanOmroepBelastingInPercent aandeelErnstigeVerstoringAanOmroepBelastingInPercent aandeelEvenementTreinAanOmroepBelastingInPercent aandeelGeplandeWijzigingAanOmroepBelastingInPercent aandeelStationBlokkadeAanOmroepBelastingInPercent aandeelVertrekkendeTreinAanOmroepBelastingInPercent aandeelVrijeTekstAanOmroepBelastingInPercent
GV 0 0 1571,86 0 16443,13 0 16691,28 0 34706,27 578,44 9501,56 5,74 0,00% 0,00% 452,90% 0,00% 4737,80% 0,00% 4809,30% 0,00%
2023-10-02 tot 2023-10-08 stationCode BEHANDELAAR BEHEERDER ERNSTIGE_VERSTORING EVENEMENT_TREIN GEPLANDE_WIJZIGING STATIONBLOKKADE VERTREKKENDE_TREIN VRIJE_TEKST totaleOmroepBelastingInSeconden totaleOmroepBelastingInMinuten Restminuten van de week omroepbelastingInPercent aandeelBehandelaarAanOmroepBelastingInPercent aandeelBeheerderAanOmroepBelastingInPercent aandeelErnstigeVerstoringAanOmroepBelastingInPercent aandeelEvenementTreinAanOmroepBelastingInPercent aandeelGeplandeWijzigingAanOmroepBelastingInPercent aandeelStationBlokkadeAanOmroepBelastingInPercent aandeelVertrekkendeTreinAanOmroepBelastingInPercent aandeelVrijeTekstAanOmroepBelastingInPercent
GV 46,01 0 3145,62 0 24953,17 0 17430,34 130,72 45705,86 761,76 9318,24 7,56 10,07% 0,00% 688,23% 0,00% 5459,51% 0,00% 3813,59% 28,60%
2023-09-25 tot 2023-10-01 stationCode BEHANDELAAR BEHEERDER ERNSTIGE_VERSTORING EVENEMENT_TREIN GEPLANDE_WIJZIGING STATIONBLOKKADE VERTREKKENDE_TREIN VRIJE_TEKST totaleOmroepBelastingInSeconden totaleOmroepBelastingInMinuten Restminuten van de week omroepbelastingInPercent aandeelBehandelaarAanOmroepBelastingInPercent aandeelBeheerderAanOmroepBelastingInPercent aandeelErnstigeVerstoringAanOmroepBelastingInPercent aandeelEvenementTreinAanOmroepBelastingInPercent aandeelGeplandeWijzigingAanOmroepBelastingInPercent aandeelStationBlokkadeAanOmroepBelastingInPercent aandeelVertrekkendeTreinAanOmroepBelastingInPercent aandeelVrijeTekstAanOmroepBelastingInPercent
GV 0 0 1395,96 0 5897,44 0 20148,94 808,54 28250,88 470,85 9609,15 4,67 0,00% 0,00% 494,13% 0,00% 2087,52% 0,00% 7132,15% 286,20%
Omroepbelasting van station GV (Hollands Spoor) 2023-10-16 tot 2023-10-22
611,15; 6%
totaleOmroepBelastingInMinuten Restminuten van de week
9468,85; 94%
Omroepbelasting van station GV (Hollands Spoor) - 202310-09 tot 2023-10-15
578,44; 6%
totaleOmroepBelastingInMinuten Restminuten van de week
9501,56; 94%
Omroepbelasting van station GV (Hollands Spoor) 2023-10-02 tot 2023-10-08
761,76; 8%
totaleOmroepBelastingInMinuten Restminuten van de week
9318,24; 92%
Omroepbelasting van station GV (Hollands Spoor) 2023-09-25 tot 2023-10-01
470,85; 5%
totaleOmroepBelastingInMinuten Restminuten van de week
9609,15; 95%