Bijlage 1 Nadere Regels uitlegschema kabel en ledingennetwerken Amsterdam
Tekst van het document
Bijlage 1 Uitlegschema kabel- en leidingnetwerken Amsterdam Afstand tussen K&L ² CAI/T
Asset
Data
E (LS)
E (MS)
E (HS)
riolering vrij verval
Afstand tussen bomen ¹
PL
Warmte
Warmte LT
W
G
OAT
Boom 1
Boom 2
Boom 3
Beschrijving
Afstand van gebouwen transp
distr
distr
transp
dist 240
dist 630
trans
transportrio hoofdpersle inzamelriool persleiding ol iding
HT
MT
distr
hoofdwater transport leiding
distributie
trans
distr
trans
Boom 1
Boom 2
Boom 3
CAI/T
CAI/ TV/ Telecom
transp 0,00m
0,50m
0,50m
0,75m
0,75m
0,75 m
2,00m
2,50 m
0,75 m
0,75m
2,50m
0,75m
0,75m
0,75m
2,00m
1,00m
0,5m
0,30m
0,3
0,75m
1,00m
1,50m
2,00m
0,25/ 0,50m
Data
Glasvezel
dist.
0,50m
0,00m
0,25 m
0,25 m
0,25 m
0,25 m
2,00m
2,50 m
0,75 m
0,75m
2,50m
0,75m
0,75m
0,75m
2,00m
1,00m
0,50m
0,30m
0,30m
0,75m
1,00m
1,50m
2,00m
0,25/ 0,50m
E (LS)
9
Electra Laagspanning
dist.
0,50m
0,25m
0,10 0,15m
0,10m
0,10m
0,10m
2,00m
2,50m
0,75 m
0,75m
2,50m
2,50m
4
2,50m
4
2,50m
4
2,00m
1,00m
0,50m
0,30m
0,30m
0,75m
1,00m
2,00m
2,00m
0,50m
transp 0,75m
0,25m
0,10m
1,00m
1,00m
1,00m
2,00m
2,50m
0,75m
0,75m
2,50m
2,50m
4
2,50m
4
2,50m
4
2,00m
2,00m
0,75m
0,30m
0,30m
0,75m
1,00m
2,00m
2,00m
1,00m
E (MS)
9
Electra Middenspanning Electra Middenspanning Electra Middenspanning
0,25m
0,10m
1,00m
0.10m
0,30m
2,00m
2,50m
0,75m
0,75m
2,50m
2,50m
4
2,50m
4
2,50m
4
2,00m
2,00m
0,75m
0,30m
0,30m
0,75m
1,00m
2,00m
2,00m
1,00m
0,25m
0,10m
1,00m
0,30m
0,30m
2,00m
2,50m
0,75m
0,75m
2,50m
2,50m
4
2,50m
4
2,50m
4
2,00m
2,00m
0,75m
0,30m
0,30m
0,75m
1,00m
2,00m
2,00m
1,00m
2,00m
2,00m
2,00m
2,00m
2,00m
3,00m
3,00m
2,00m
2,00m
3,00m
2,50m
4
2,50m
4
2,50m
4
2,00m
2,00m
2,00m
5,00m
5,00m
2,00m
2,00m
2,00m
2,00m
2,00m
9
E (HS)
dist. 0,75m 240Al dist. 0,75m 630Al
Electra Hoogspanning transp 2,00m
Riolering Transportriool vrij verval Inzamelriool
transp 2,50m
2,50m
2,50m
2,50m
2,50m
2,50m
3,00m
3,00m
-
3,00m
3,00m
3,00m
3,00m
3,00m
2,00m
3,00m
3,00m
3,00m
3,00m
1,50m
3,00m
4,00m
5,00m
5,00 m
dist.
0,75m
0,75m
0,75m
0,75m
0,75m
0,75m
2,00m
-
-
0,75m
3,00m
1,00m
1,00m
0,75m
2,00m
1,00m
1,00m
1,00m
1,00m
1,50m
1,00m
1,50m
2,00m
3,00 m
Persleiding riolering onder druk Hoofdpersleiding*
transp 0,75m
0,75m
0,75m
0,75m
0,75m
0,75m
2,00m
3,00m
0,75m
0,75m
3,00m
0,75m
0,75m
0,3m
2,00m
1,00m
1,00m
0,75m
0,75m
1,50m
1,00m
1,50m
2,00m
2,00 m
transp 2,50m
2,50m
2,50m
2,50m
2,50m
2,50m
3,00m
3,00m
0,75m
-
3,00m
3,00m
3,00m
3,00m
3,00m
-
3,00m
3,00m
3,00m
3,00m
4,00m
5,00m
10,00m *
Warmtenet transp 0,75m Hoogtemperatuur (HT)
0,75m
0,75m
2,50m
4
2,50m
4
2,50m
4
2,50m
4
3,00m
1,00m
1,00m
3,00m
0,40m ³
0,40m ³
0,30m
2,00m
1,50m
1,5m
1,00m
1,00m
0,75m
1,00m
1,50m
2,00m
1,50m
Midden temperatuur (MT)
Warmte
Warmte Warmtenet Lage LT Temperatuur Hoofdwaterleiding * (>600 mm) W
dist.
0,75m
0,75m
0,75m
2,50m
4
2,50m
4
2,50m
4
2,50m
4
3,00m
1,00m
1,00m
3,00m
0,40m ³
0,40m ³
0,30m
2,00m
1,50m
1,50m
1,00m
1,00m
0,75m
1,00m
1,50m
2,00m
1,50m
dist.
0,30m
0,30m
0,30m
2,50m
4
2,50m
4
2,50m
4
2,50m
4
3.,00m
0,75m
0,75m
3,00m
0,30m
0,30m
0,30m
2,00m
1,50m
1,50m
0,3
0,30m
0,30m
1,00m
1,50m
2,00m
1,50m
transp 2,00m
2,00m
2,00m
2,00m
2,00m
2,00m
2,00m
2,00m
2,00m
2,00m
3,00m
2,00m
2,00m
2,00m
2,00m
2,00m
2,00m
2,00m
2,00m
2,00m
2,00m
2,00m
2,00m
3,00m
transp 1,00m
1,00m
1,00m
2,00m
2,00m
2,00m
2,00m
3,00m
1,00m
1,00m
3,00m
1,50m
1,50m
1,50m
2,00m
-
1,00m
1,00m
1,00m
2,00m
2,00m
2,00m
2,00m
3,00m
dist.
0,5m
0,5m
0,5m
0,75m
0,75m
0,75m
2,00m
3,00m
1,00m
1,00m
3,00m
1,50m
1,50m
1,50m
2,00m
1,00m
0,5m
0,50m
0,5m
2,00m
2,00m
2,00m
2,00m
2,00m
transp 0,30m
0,30m
0,30m
0,30m
0,30m
0,30m
5,00m
3,00m
1,00m
1,00 m
3,00m
1,00m
1,00m
1,00m
2,00m
1,00m
0,50m
0,30m
0,30m
0,75m
1,00m
2,0m
2,00m
<200MM = 2 m. >200mm = 3,5m.
dist.
0,30m
0,30m
0,30m
0,30m
0,30m
0,30m
5,00m
3,00m
1,00m
1,00m
3,00m
1,00m
1,00m
1,00m
2,00m
1,00m
0,50m
0,30m
0,30m
0,75m
1,00m
2,00m
2,00m
1,20m
transp 0,75m
0,75m
0,75m
0,75m
0,75m
0,75m
2,00m
1,50m
1,50m
1,50m
3,00m
0,75m
0,75m
0,30m
2,00m
2,00m
2,00m
0,75m
0,75m
1,00m
1,50m
2,00m
1,50m
Drinkwater
G
O.A.T.
Gas Ondergronds Afval Transport
1 Volgens gemeente A'dam toolbox: Boom 1 hoogte 6-10m. Boom 2 hoogte 10-15m. Boom 3 hoogte >15m 2 Afstand tussen kabels en leidingen, dagmaat 3 Leidingen diameter <150mm; afstand =0,20m. Leidingen diameter >0,15m; afstand =0,40m. Afstand tussen buizen, van rand tot rand. 4 Hier mogen wel andere nutspartijen tussen liggen. Een kleinere afstand tussen elektra en warmte is alleen toegestaan mits dit is aangetoond dmv een kabelbelastbaarheidsberekening.
Uitlegschema Amsterdam Diameter
Dekking
vrij werkruimte 1
Beschrijving transp.
dist.
huisaansl.
transp.
dist.
huisaansl.
transp.
dist.
huisaansl.
CAI/T
CAI/ TV/ Telecom
80 - 100mm
25 - 50mm
-
0,60m
0,60/0,50m
0,50m
0,30m
0,30m
0,30m
Data
Glasvezel
40mm-50mm
40mm-50mm
-
0,60m
0,60/0,50m
0,50m
0,30m
0,30m
0,30m
-
70mm
70mm
-
0,60m
0,50m
-
0,25m
0,25m
100mm
100mm
100mm
0,90m
0,70-0,90m
0,70-0,90m
0,25m
0,25m
0,25m
140mm
-
-
1,20m
-
-
2,00m
-
-
0,30-0.40m
0,25 m
125 - 160mm
>1,80m
0,80m
0,34m
2,00m
0,50m
0,50m
0,30-1,80m
0,30-1,80m
125 - 160mm
>1,80m
>0,80m
125 - 160mm
2,00m
0,50m
125 - 160mm
E (LS) E (MS) E (HS) DWA
Electra Laagspanning Electra Middenspanning Electra Hoogspanning Droogweerafvoer (riool)
DWA + HWA HWA/ RWA
Hemelwaterafvoer (riool)
-
0,30-1,50m
125 - 160mm
-
>0,80m
0,34m
-
0,50m
0,50m
PL
Persleiding
0.063-1,80
-
-
>0,80m
-
-
0,50m
-
-
Warmte HT/ MT
Warmtenet Hoge/ Midden temperatuur
500-1000mm
500-1000mm
<160mm
1,00m
0,80 m
0,50m/0,75m
0,50m
0,50m
0,50m
Warmte LT
Warmtenet Lage Temperatuur
250-400mm
250mm
0,80m/ 1,00m
0,80m/ 1,00m
0,50m/0,75m
0,30m
0,30m
0,30m
W
Drinkwater
0,315-1,20m
0,015-0,315m
0,015-0,15m
1,00m
0,80m
0,80m
1,50m
0,5m
0,50m
G
Gas
75-400mm
75- 400mm
32-63mm
0,80m
0,80m
0,50m
0,25m
0,25m
0,25m
O.A.T.
Ondergronds Afval Transport
400mm
400mm
400mm
1m to 1,5m
2,6 - 3,2m
2,6 - 3,2m
0,50m
2
0,50m
2
0,50m
1. beide zijden vanaf buitenkant leiding/buis 2. Gebaseerd op persriool-metingen